Jandy Versa Plumb VPK-CVSTD Скачать руководство пользователя страница 2

Filter to Heater

Connector

Pump to Filter

Connector

A.

B.

Heater to Chlorinator

Connector

C.

A.

B.

C.

A.  CV Standard Kit (VPK-CVSTD)

Figure 1.  CV Standard Equipment Pad

WARNING

In order to prevent risk of electrical shock, 

fire, or Carbon Monoxide poisoning, before 

beginning the installation of the Jandy Pro 

SeriesVersa Plumb Kit, be sure to do the 

following: 

  •  Turn off all elctrical power, gas supply and 

 

other sources of power to the pool equipment.  

  •  Follow the pool filter’s installation instructions 

to properly drain the filter for service.

WARNING

In order to minimize the possibility of ingesting 

potentially toxic substances which could cause 

injury from illness, including death, whenever 

the instructions call for the use of “CPVC 

cement”, use a cement that has been listed by 

NSF

®

 or an equivalent Nationally Recognized 

Testing Laboratory (NRTL) or certification body. 

Read and follow the cement manufacturer’s 

danger and cautionary statements and 

instructions for use.  

NEVER

 start pump while standing 

within five (5) feet of the filter. Starting 

the pump while there is pressurized 

air in the system can cause the filter 

lid to be blown off, which can cause 

death, serious personal injury or 

property damage.

Before restarting the system, consult the 

installation and operating manuals for 

each piece of equipment for proper startup 

procedures. 

WARNING

1.  Position the pool suction and return lines in front of 

the equipment pad location.

2.  Position the various equipment pad components. 

Bring the suction and return piping up through the 

perforated holes on the template.

3.  Connect the pump to the suction lines (pool only or 

pool/spa combo) using CPVC cement and primer. 

The length of pipe into the suction port of the pump 

should be a minimum of four (4) times the pipe 

diameter.

4.  Use CPVC cement and primer and connect the 

pump to the filter using the sweep elbow with the 

½” NPT plug component of the kit, marked as “A” 

in figure 1.  This positions the filter.

5.  Use CPVC cement and primer and connect the filter 

to the heater using the straight length of pipe with 

union nuts on both ends, marked as “B” in figure 1. 

This positions the heater. 

6.  Attach the check valve (marked as “C” 

in figure 

1

) to the outlet of the LXi™ making sure the flow 

arrow points in the correct direction.  

7.  If desired, attach a salt chlorinator spool or a blank 

spool assembly provided in this kit to the check 

valve and then run the return line from the spool to 

the trench using CPVC cement and primer.

NOTE  

Also included in the Versa Plumb Kit are two (2)

additional 3-way valves and a spare 12” of pipe 

for your use in the event that you add additional 

components on the return system.

3.  Installation Instructions 

Page 2

 

Jandy

®

 Pro Series Versa Plumb

®

 Kits   

|

   Replacement Kit Instructions

Page 2

 

Содержание Versa Plumb VPK-CVSTD

Страница 1: ...fied in pool equipment by the juris diction in which the product is installed where such state or local requirements exist In the event no such state or local requirement exists the service provider o...

Страница 2: ...ls for each piece of equipment for proper startup procedures WARNING 1 Position the pool suction and return lines in front of the equipment pad location 2 Position the various equipment pad components...

Страница 3: ...suction port of the pump should be a minimum of four 4 times the pipe diameter 4 Use CPVC cement and primer and connect the pump to the filter using the sweep elbow with the NPT plug component of the...

Страница 4: ...e diameter 4 Use CPVC cement and primer and connect the pump to the filter using the sweep elbow with the NPT plug component of the kit marked as A in figure 6 This positions the filter 5 Use CPVC cem...

Страница 5: ...ector Filter to Heater Connector with Solar Stubbs 12 in Pipe 3 Way Valve Qty 2 Pump to Filter Connector Heater to Chlorinator Connector Blank Spool Figure 7 CV Standard Kit 4 Parts List A CV Standard...

Страница 6: ...nes Blank Spool Pump to Filter Connector Filter to Heater Connector Heater to Chlorinator Connector B l a n k S p o o l Return Lines Suction Lines Figure 10 CV Standard Installation Diagram Figure 11...

Страница 7: ...ater to Chlorinator Connector Chlorinator Spool Filter to Heater Connector Return Lines Suction Lines Figure 12 CS Standard Installation Diagram CS Standard Page 7 Jandy Pro Series Versa Plumb Kits Re...

Страница 8: ...Products Safety Commision has determined that the temperature of the water at the INLET to a pool or spa must not exceed 122 F 50 C NOTE The water in a spa should never exceed 104 F 40 C Water tempera...

Страница 9: ...Figure 14 Versa Plumb Installation Diagram CV Standard and CV Solar Kit Page 9 Jandy Pro Series Versa Plumb Kits Replacement Kit Instructions...

Страница 10: ...Figure 15 Versa Plumb Installation Diagram CS Standard Page 10 Jandy Pro Series Versa Plumb Kits Replacement Kit Instructions Page 10...

Страница 11: ...NOTES Page 11 Jandy Pro Series Versa Plumb Kits Replacement Kit Instructions...

Страница 12: ...m 2016 Zodiac Pool Systems Inc ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks referenced herein are the property of their respective owners H0...

Отзывы: