Jandy Stealth SHPM Скачать руководство пользователя страница 5

1.2  Pool Pump Suction Entrapment Prevention Guidelines

 

WARNING

Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swim-

ming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. 

The following guidelines 

provide information for pump installation that minimizes the risk of injury to users of pools, spas, and hot tubs:

Entrapment Protection 

- The pump suction system must provide protection against the hazards of suction 

entrapment.

Suction Outlet Covers

 - All suction outlets must have correctly installed, screw-fastened covers in place. All 

suction outlet (drain) assemblies and their covers must be properly maintained. Suction outlets (drain) assem

-

blies and their covers must be listed/certified to the latest version of ANSI

®

/ASME

®

 A112.19.8 or its successor 

standard, ANSI/APSP-16. They must be replaced if cracked, broken, or missing. 

Number of Suction Outlets Per Pump

 - Provide at least two (2) hydraulically-balanced main drains, with cov

-

ers, as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets) on 

any one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1.

The system 

must

 be built to include at least two (2) suction outlets (drains) connected to the pump whenever 

the pump is running. However, if two (2) main drains run into a single suction line, the single suction line may be 

equipped with a valve that will shut off both main drains from the pump. The system shall be constructed such 

that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1.

More than one (1) pump can be connected to a single suction line as long as the requirements above are met.

Water Velocity

 - The maximum water velocity through the suction outlet assembly and its cover for any suc-

tion outlet must not exceed the suction fitting assembly and it’s cover’s maximum design flow rate.  The suction 

outlet (drain) assembly and its cover must comply with the latest version of ANSI/ASME A112.19.8, the standard 

for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs, or its successor standard, 

ANSI/APSP-16.

If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suc

-

tion hydraulic system must be six (6) feet per second or less, even if one (1) main drain (suction outlet) is com

-

pletely blocked. The flow through the remaining main drain(s) must comply with the latest version of ANSI/ASME 

A112.19.8 or its successor standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming 

Pools, Wading Pools, Spas, and Hot Tubs.

Testing and Certification

 - Suction outlet assemblies and their covers must have been tested by a nationally 

recognized testing laboratory and found to comply with the latest version of ANSI/ASME A112.19.8 or its succes-

sor standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, 

and Hot Tubs.

Fittings

 - Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction outlets). 

Avoid fittings which could cause an air trap. 

Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical 

Officials (IAPMO) standards.

SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for 

wading pools, shallow pools or spas containing bottom drains, unless the pump is 

connected to at least two (2) functioning suction outlets.

 

WARNING

 

CAUTION

The 3-phase SHPF series pumps utilize non-thermally protected motor assemblies. NRTL Listed Motor Controller 

with internal motor running overload protection or external motor running overload are required during the final 

installation of the pump assembly. Overloads shall be set at a maximum of 125% of the full-load current rating of 

the pump motor assembly.

Page 5 

ENGLISH

Jandy

®

 Pro Series Stealth

 Pumps   

|

   Operation Manual

Содержание Stealth SHPM

Страница 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Страница 2: ...2 Section 5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 13 Section 6 Troubleshooting 14 6 1 Troubleshooting 14 Section 7 Product Specifications and Technical Data 15...

Страница 3: ...without the test button being pushed a ground current is flowing indicating the possibility of electri cal shock Do not use the pump Disconnect the pump and have the problem corrected by a qualified...

Страница 4: ...o ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 1...

Страница 5: ...eed the suction fitting assembly and it s cover s maximum design flow rate The suction outlet drain assembly and its cover must comply with the latest version of ANSI ASME A112 19 8 the standard for S...

Страница 6: ...r strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow...

Страница 7: ...level isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing Some Safety Vacuum Release System SVRS de vic...

Страница 8: ...installation requirements NOTE To prevent entrapment the system must be built so that it cannot operate with the pump drawing water from only one 1 main drain At least two 2 main drains must be connec...

Страница 9: ...must be adequate to minimize voltage drop during the start up and operation of the pump See Table 2 for recommended wire sizes RECOMMENDED MINIMUM WIRE SIZE FOR SHP PUMPS Distance from Sub Panel 0 50...

Страница 10: ...ck hazard resulting in severe personal injury or death WARNING Due to the potential risk of fire electric shock or injuries to persons Jandy Pro Series Pumps must be installed in accordance with the N...

Страница 11: ...KS WARNING When pressure testing the system with water it is very important to make sure that the pump basket lid on the filter pump is completely secure WARNING Do not pressure test above 35 PSI Pres...

Страница 12: ...or a suction leak and then repeat Steps 2 through 7 Section 5 Service and Maintenance 5 1 Routine Maintenance Inspect the pump basket for debris by looking through the clear pump lid Remove any debris...

Страница 13: ...the o rings Drain Plug with O ring Set R0446000 3 Keep the motor covered and dry NOTE Covering the pump with plastic will create condensation and this moisture will damage the pump The best way to pro...

Страница 14: ...the lid o ring and place on the lid Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid Turn the pump back on Air leaks are still present Check the suction side pipi...

Страница 15: ...g Mech Seals SHPF 5 0 R0445201 3 Impeller Replacement Kit SHPF 50 R0807204 3 Impeller Replacement Kit SHPF 75 R0807203 3 Impeller Replacement Kit SHPF 1 0 1 0 2 R0807202 3 Impeller Replacement Kit SHP...

Страница 16: ...and Ceramic All R0479400 6 Body Pump SHPF SHPM All R0445601 7 Motor Mounting Foot Assembly w Screws SHPF SHPM All R0445700 8 Lid w Locking Ring Seal All R0445800 9 Blue Pressure Test O ring All R0479...

Страница 17: ...pecifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPF 50 50 208 230 115 4 4 4 5 8 8 2 2 30 lbs 311 8 SHPF 75 75 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPF 1 0 1 0 20...

Страница 18: ...SHPM 2 5 2 5 208 230 11 0 10 0 2 2 57 lbs 331 8 SHPM 1 5 2SPD 1 5 230 7 2 3 0 2 2 52 lbs 321 8 SHPM 2 0 2SPD 2 0 230 10 0 3 5 2 2 57 lbs 325 8 SHPM 2 5 2SPD 2 5 230 11 0 4 0 2 2 64 lbs 331 8 113 8 16...

Страница 19: ...NOTES Page 19 ENGLISH Jandy Pro Series Stealth Pumps Operation Manual...

Страница 20: ...ol Systems LLC 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com 2017 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under licens...

Отзывы: