LX and LT Pool Heaters

Page 1

SECTION 1.

General  Information

1A. Introduction

This manual contains information for the proper

installation and operation of the LX and LT pool/spa

heaters. Certain sections are specific to United States or

Canadian installations, and are labeled United States or

Canada. Procedures in this manual must be followed

exactly. To obtain additional copies of this manual contact

Waterpik Technologies. For address information see back

cover.

1B. Description

The Laars LX and LT have no standing pilot burner.

They exceed the requirements of energy conservation

regulations such as those in California, Hawaii, New York,

Oregon and other states which require that a pool heater

not have a continuous ignition source.

The heaters are designed to operate in conventional

swimming pool and spa equipment arrangements. They

require 120V or 240V, 60 Hz electrical power.

The Laars LX and LT are certified by International

Approval Services, Inc. to comply with latest editions of

applicable U.S./Canadian combined standard for gas-fired

pool heaters. In the United States, the applicable standard

is ANSI Standard Z21.56 for gas-fired pool heaters. In

Canada, it is Standard CSA 4.7. As such, the heater

carries both the AGA and CGA logos.

The heaters have been designed specifically to heat

fresh water swimming pools and spas, and with proper

installation and care, they will provide years of reliable

service. Do not use the heaters to maintain pool or spa

water temperature below 70°F. Do not use them as heating

boilers or general service water heaters or to heat salt

water. For special applications, consult your Waterpik

Technologies dealer.

 

DANGER

Improper installation or servicing can cause

property damage, injury or death due to fire,

asphyxiation or carbon monoxide poisoning.

1C. Warranty

The LX and LT are sold with a limited factory

warranty. A copy of the warranty is included in a plastic

bag inside the heater and on the back cover of this manual.

The home owner should fill out the warranty registration

card included in the plastic bag and return it to Waterpik

Technologies. The warranty does not cover damage caused

by improper installation, operation, or field modification;

or damage to the heat exchanger caused by corrosive

water. See Section 3D for guidelines on pool water

chemistry.

SECTION 2.

Installation Instructions

2A. General Requirements

All gas-fired products require correct installation to

assure safe and satisfactory operation. The requirements

for pool heaters include the following:

1.

Appropriate site location and clearances.

2.

Sufficient supply of clean air for combustion and

ventilation.

3.

Proper venting of products of combustion.

4.

Properly sized gas pipe.

5.

Properly sized gas meter.

6.

Adequate water flow.

In the United States, installation must be in

accordance with local codes and the most recent edition of

the National Fuel Gas Code, ANSI Z223.1. The Code can

be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02269

In Canada, install the heater in accordance with

local codes and the most recent edition of the Installation

Codes for Gas Burning Appliances, CAN 1-B149.1 & .2.

The Canadian Gas Codes are available from:

Canadian Gas Association

55 Scarsdale Road

Don Mills, Ontario

M3B 2R3

2A-1.Special Precautions

Liquefied petroleum (LP) gas is heavier than air.

Therefore, a pool heater using LP gas is subject to special

installation rules. Consult local codes and fire protection

authorities about specific installation restrictions.

Fuel gas and its combustion products are known to

cause cancer or harm the reproductive process. Follow

these installation instructions and applicable codes exactly

to avoid this hazard.

2B. Heater Assembly and Preparation

The LX or LT can be installed in a variety of ways,

some of them requiring preparation or assembly in the

field.  Water connections are provided on the right side of

the heater but can be changed to the left side by reversal of

the heat exchanger.

Содержание pool/spa heater

Страница 1: ...lt causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions I...

Страница 2: ...ief Valve 14 2I 5 Automatic Chlorinators Chemical Feeders 15 2J Start Up and Adjustment 15 2J 1 Normal Operation 15 2J 2 Start Up 15 2J 3 Gas Pressure 16 2J 4 Adjustment of Water Pressure Switch 16 2J 5 Water Temperature Rise 17 SECTION 3 Operating Instructions 3A Start Up Procedure 18 3B Temperature Controls 18 3B 1 Information Displayed 19 3B 2 Turning The Heater On Or Off 19 3B 3 Setting Pool A...

Страница 3: ...luded in a plastic bag inside the heater and on the back cover of this manual The home owner should fill out the warranty registration card included in the plastic bag and return it to Waterpik Technologies The warranty does not cover damage caused by improper installation operation or field modification or damage to the heat exchanger caused by corrosive water See Section 3D for guidelines on poo...

Страница 4: ...proper operation 2C Heater Location 2C 1 Installation Information The LX and LT can be installed outdoors or indoors as outlined in later sections In either case location must be selected with consideration of vent gas exhaust and in the case of indoor installation the location must have suitable provisions for combustion and ventilation air Avoid placing the heater in locations where it can cause...

Страница 5: ...lso apply such as provision of ample uncontaminated air for combustion and ventilation 2F Indoor Installation 2F 1 Preparation of Heater for Indoor Installation If the LX or LT is to be installed indoors its exhaust discharge grill must be converted to a collar for vent pipe connection The necessary vent collar gasket and screws can be ordered as parts kit R0331403 or R0331405 see parts list in Se...

Страница 6: ...n Codes for Gas Appliances CAN 1 B149 1 2 Undersize pipe can result in inadequate venting and oversize pipe can result in vent condensation In either case the result can be release of combustion products to the indoors This can cause serious injury or death by carbon monoxide poisoning or asphyxiation 2F 2 Special Location Requirement Virtually all local installation codes require that a heater in...

Страница 7: ... be a Category I Fan Assisted appliance They are intended for standard vertical venting per tables provided in most local codes for Category I Fan Assisted appliances If the local code does not include such tables refer to the National Fuel Gas Code Z223 1 or the Canadian Installation Codes for Gas Appliances CAN 1 B149 1 2 Note that the tables for fan assisted appliances include both maximum and ...

Страница 8: ...aximum 10 5 2 7 14 3 5 Figure 7 The Proper Design for a Sediment Trap Drip Leg Table 4 Natural Gas Pipe Size Requirements Distance from Gas Meter 0 50 feet 50 100 feet 100 200 feet Heater 0 15 m 15 30 m 30 60 m Size in in in 250 1 1 1 4 1 1 4 400 1 1 4 1 1 2 1 1 2 Notes 1 These numbers are for natural gas 0 65 Sp Gr and are based on 1 2 inch 3 45 kPa water column pressure drop Check supply pressur...

Страница 9: ...EMP SENSOR J4 1 J4 2 0 6 1 6 1 7 5 7 5 32 5 6285 5 5 3 5 5 3 5 5 5 3 5 5 3 5 5 5 5 5 5 5 5 5 5 2 8 1 6 5 5 2 8 1 6 5 1 6 5 9 1 1 7 9 3 6 3 6 9 1 7 9 1 7 3 6 3 6 0 9 0 9 0 9 0 9 7 5 3 5 6 6 8 5 6 7 0 7 6 7 6 0 1 8 5 6 7 9 1 7 6 7 2 5 3 5 6 6 8 5 6 7 6 9 9 1 7 2 1 2 1 7 5 2 1 9 9 8 6 5 7 5 1 6 2 5 0 5 7 5 1 6 2 5 0 5 5 5 5 2 5 2 5 2 5 5 5 3 1 3 8 3 1 5 3 7 9 2 5 5 9 Wiring Diagram 7 2 7 5 8 5 5 2 1 ...

Страница 10: ... connected to either tab on the terminal block the connections are not polarity sensitive Plug the fifteen pin connector into the receptacle The connector is keyed so it will fit in only one orientation Electrical wiring must be in accordance with the latest edition of the National Electric Code NEC ANSI National Fire Protection Association NFPA 70 unless local code requirements indicate otherwise...

Страница 11: ...e it A number will appear on the display for approximately 5 seconds This first number can be ignored After the first number disappears a second number will appear in the display window It will consist of 4 digits followed by a revision level REV _ If the revision level displayed here is at H or higher it will accommodate a Laars LX heater without any modification If the chip is at a revision G or...

Страница 12: ...er is disabled The heater functions can be controlled only at the RS unit However sensor data is displayed at both the heater and the RS unit To temporarily use the heater controls use a thin object to depress the button marked RS SERVICE The RS ONLINE indicator will disappear from the heater display All functionality has now been returned to the control on the heater In this mode the RS unit has ...

Страница 13: ...ontrol panel There are quick disconnects at the end of the wires 15 Remove the inlet outlet header side cover plate located under the inlet outlet header There are four philips head screws one in each corner holding it in place 16 Slide the upper right side panel up and out of the corner posts and place it aside 17 Remove the left side cover panel held to the lower panel with two philips head scre...

Страница 14: ... one in each corner 26 Route the wires that attach to the temperature sensor along the copper siphon loop back to the right side of the heater Reconnect the wires to the tabs on the back of the control panel marked as J4 1 and J4 2 27 Use plastic wire ties to refasten the temperature sensor and high limit switch wires to the copper siphon loop Bundle the wires near the control panel and fasten the...

Страница 15: ...he top of the heater Be careful not to pinch any wires Replace the two screws on the bottom flange to hold the cover in place 47 Replace the front panel door 2I 2 Pool Spa Piping Systems Figure 15 illustrates typical piping for pool equipment in pool spa combination pools With their electronic temperature controls the LX and LT are particularly suited for this type of pool installation The heater ...

Страница 16: ... Technologies PRV kit into the blind threaded hole on the top of the inlet outlet header 2 Using the countersink in the center of the blind hole as a guide drill a 1 4 inch hole through the plastic 3 Open the hole by reaming it with a 3 8 inch drill bit 4 Open the hole again by reaming it with a 1 2 inch drill bit Initially drilling a 1 2 inch hole without reaming may cause the bit to grab on the ...

Страница 17: ...tton until the indicator on the LCD screen aligns with OFF Now press and release the button again until the indicator on the LCD screen aligns with the desired setting either POOL or SPA To reset the model LT press and release the mode button until the indicator lights for the SPA and POOL settings are off Then press and release it again until the indicator light for the desired setting is back on...

Страница 18: ...ff Setting the switch to close at too low of a flow can damage the appliance Do not operate this heater outdoors at temperatures below 20 degrees Fahrenheit F 7 degrees Celsius C 2J 2 Start up Confirm that pool water is flowing normally through the pool system and equipment Start the heater in accordance with the Operating Instructions section of this manual with particular attention to the lighti...

Страница 19: ...low even though flow through the filter system will vary depending on how dirty the filter is For most installations an external bypass valve is not needed in the heater water piping This is due to the large size of the heater s internal bypass valve If the pump flow rate is known to significantly exceed 125 gpm 7 9 l s an external bypass may be needed to assure proper heater operation Water flow ...

Страница 20: ... from this reading This difference is the temperature rise Refer to Table 8 If your measured temperature rise is within the range designated for your heater skip steps 6 through 8 6 Locate the bypass adjustment screw on the right hand side of the header see figure 20 Loosen the nut so that the screw can be adjusted A slight water leak past the nut may be expected Turn the screw counterclockwise to...

Страница 21: ...en there is water flowing through the heater the filter pump is on the water temperature is displayed in the right most of two bar graphs in the center of the screen This bar graph is labeled as Water Temperature The selected thermostatic setting either Pool or Spa is displayed as a bar graph directly to the left of the water temperature bar graph This bar graph is labeled as Thermostat Setting No...

Страница 22: ...the heater is OFF It is now necessary to set the thermostat to the desired pool or spa setting 3B 3 Setting Pool and Spa Temps Changing from Fahrenheit to Celsius The Model LX heater displays temperature in Fahrenheit units when powered up To switch to Celsius press the F C button Once the desired temperature units are selected the thermostat can be set The left most button below the LCD screen la...

Страница 23: ... switch 1 Broken split pinched or disconnected fan switch tubing 1 Check tubing and replace if necessary 2 Fan not operating 2 Correct fault or replace fan Refer to qualified service personnel 3 Fan running slow or premature fan failure 3 Verify proper wiring for 120VAC or 240VAC Refer to qualified service personnel 4 Air flow restricted at intake or discharge 4 Check for proper clearances around ...

Страница 24: ...alve control knob counterclockwise to ON see Figure 22 5 Replace the heater door 6 Turn on electrical power to the heater 7 Turn on the filter pump 8 Set the heater controls to the SPA position mode If the temperature of the water exceeds the thermostat setting it is necessary to increase the thermostat setting to exceed the water temperature Adjust the thermostat setting to be greater than the wa...

Страница 25: ...o to next step 8 Turn gas control knob counterclockwise to ON A This appliance does not have a pilot light It is equipped with an ignition device which automatically lights the heater Do NOT try to light the burners by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO I...

Страница 26: ...he week It should be reset to the 78 F 26 C level before expected usage keeping in mind to allow enough lead time for the water to reach the desired temperature 3D 2a Spa Water Chemistry Maintaining safe water conditions in a spa can only be done by regular water changes and the proper addition of sanitizing chemicals Kits are available from your local pool supply dealer for making the various tes...

Страница 27: ...eater is not going to be used for a long period of time shut it down completely following the instructions in Section 3C 2 Shutdown or the lighting and shutdown instructions posted inside the heater 3G 2 Winterizing If you don t plan to use the pool or spa over the winter and your area is subject to freezing temperatures have a qualified professional technician perform the following steps to prote...

Страница 28: ...perature control g Control circuit fuse 6 Perform a temperature rise test in accordance with Section 2J 5 7 If the heater is equipped with a pressure relief valve clean any accumulated corrosion and make sure that water runs freely through it 8 Inspect combustion chamber and burner for corrosion and indication of improper operation 9 Regularly inspect electrical controls for deterioration Repair a...

Страница 29: ...10444900 33 RetainerBracket Temp Sensor All 10447300 34 Screw RetainerBracket All F0009100 35 IgnitionControl All R0328800 36 Pressure Switch Assy All R0334500 37 Pressure Switch 2 psi All R0013200 38 SiphonLoop All R0334600 39 High Limits Set All R0023200 40 High Limit 135 F All R0022700 41 High Limits 150 F All R0023000 42 Harness High Limit Switch All R0334700 43 Retainer Plates High Limit Set ...

Страница 30: ...SEE NEXT PAGE FOR DETAIL 20 21 22 23 25 SEE NEXT PAGE FOR DETAIL 44 54 55 57 SEE NEXT PAGE FOR DETAIL 58 59 60 60 61 63 64 65 66 67 68 69 70 71 72 73 10 9 SEE NEXT PAGE FOR DETAIL 45 24 62 74 56 36 38 37 5C Exploded View 5C 1 Overview 77 ...

Страница 31: ...LX and LT Pool Heaters Page 29 2 3 4 5 7 8 11 11 12 16 17 15 18 19 14 35 27 29 37 42 40 41 52 53 51 32 31 30 34 33 43 43 6 5C 2 Detail View 77 ...

Страница 32: ...horized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer 9 Overheating incorrect wire runs improper electrical supply collateral damage caused by failure of O Rings DE grids or cartridge elements or damage c...

Отзывы: