Page 11

pool temperature and the heater toggle switch on. 
Do not disconnect high limit or pressure switches. 
The heater will only fire when time clock turns on 
the filter pump.

3.4.5  Connect Freeze Protection Sensor to 

Printed Circuit Board

Carefully uncoil copper tube and feed it through 
bottom of the enclosure without kinking the 
capillary tube. Expose the capillary tube to outside 
air. Ensure that wires from sensor are connected to 

Pins 1 and 2 on the terminal block. Set sensor to 
38°.  Refer to Figure 6.

3.4.6  Set Jumpers and Diode

The system default from the factory is set up for 
a single-speed filter pump. Set jumpers according 
to your pump setup by following Figure 7 below. 
A diode stored in pin 3 of the terminal block 
must be placed into the diode location for two-
speed filtration pump installation.

Figure 7. 

Jumper Settings Diagram

Figure 6. Pool Link Wiring Diagram

To
Heater.
Connect in
Series with
Thermostat

FLTR/
HI

CLNR/
LO

Contacts

Motor

Filter

Time Clock

120
VAC

To
Freeze

Sensor

P5

P1

P2

P3

1

2

3

Move Jumper to
pins 1 & 2 to disable
heater cooldown

To JVA for In-Floor
Cleaning System or 
Water Feature

FLTR

TCLK

24 VAC from 
Transformer

P6

JP1

(Refer to figures 
3 and 4)

Both jumpers are 
in the A position.

Filter Pump

must be a single
speed.

NOTE:

P3

P2

P1

A

B

Move jumper to
pins 1 & 2 to
disable heater
cooldown

3 2 1

P5

To 24 VAC
Power Supply

To Freeze

Sensor

To
Heater

1

2

3

4

5

6

Time Clock:

P3 - Main Filter

Pump

P6

diode

Single - Speed Filter
Pump and Pool Cleaner
Booster Pump Setting:
(Factory Default)

A B

Diode is stored
here for future
use.

Time Clock:
P3 - Main Filter
Pump

P3

diode

P2

P1

A

B

Move jumper to
pins 1 & 2 to
disable heater
cooldown

3 2 1

P5

To 24 VAC
Power Supply

To Freeze

Sensor

To

Heater

1

2

3

4

5

6

P6

Two - Speed Filter
Pump Setting:

A B

Move both jumpers to 
the B position.  Remove 
diode from storage 
location (TB1) and install 
as indicated with the white 
band towards the bottom.

Содержание POOL LINK

Страница 1: ...installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property d...

Страница 2: ......

Страница 3: ...ing System 10 3 4 3 Wire Time Clock to Printed Circuit Board 10 3 4 4 Connect Heater to Printed Circuit Board 10 3 4 5 Connect Freeze Protection Sensor to Printed Circuit Board 11 3 4 6 Set Jumpers an...

Страница 4: ...ant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since the...

Страница 5: ...l aide d un thermom tre pr cis Ne pas utiliser une cuve de relaxation imm diatement apr s un exercice fatigant L utilisation prolong e d une cuve de relaxation peut tre dangereuse pur la sant Ne pas p...

Страница 6: ...Power Centers required and sold separately 6613 Standard Power Center with mounting brackets 6614 Sub Panel Power Center with mounting brackets 6613AP and 6614AP PureLink Sub Panel Power Center with m...

Страница 7: ...t Rating High voltage 25 A 3HP 240 VAC 1 HP 120 VAC 1500 Watts Incandescent Low Voltage Class Two 1 A 24 VAC Service Switch All Circuits located at Power Center Dimensions Pool Link Control System 661...

Страница 8: ...t isolation and or branch circuit protection installed upstream of the Power Center Depending on which equipment is being controlled run or conduit from the power supply panel to the bottom of the Poo...

Страница 9: ...do not run high voltage in this com part ment From Main Power Ground White White Black Black To Motor Terminals of Filter Time Clock See Figure 6 Two Speed Pump Wiring Relay 1 P2 socket Relay 2 P1 so...

Страница 10: ...VA is activated when the filter pump time clock turns the system on The JVA will rotate every 20 minutes until the time clock turns the filter pump off 3 4 3 Wire Time Clock to Printed Circuit Board C...

Страница 11: ...e 6 Pool Link Wiring Diagram To Heater Connect in Series with Thermostat FLTR HI CLNR LO Contacts Motor Filter Time Clock 120 VAC To Freeze Sensor P5 P1 P2 P3 1 2 3 Move Jumper to pins 1 2 to disable...

Страница 12: ...the three pin 24 VAC plug from the transformer into the three pin terminal P5 on the back of the Control System PCB see Figure 8 Mount the Bezel to the Control System using the screws provided Figure...

Страница 13: ...ll other DIP switches equal the number of hours e g DIP switch 4 equals 4 hours of high speed Turn on one and only one DIP switch for high speed 4 4 Heater Cool Down Whenever the time clock turns on t...

Страница 14: ...Page 14 Notes...

Страница 15: ...Page 15 Notes...

Страница 16: ...and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals suc...

Отзывы: