Jandy

®

 Pro Series, LXi Maintain Heat Relay   

|

   Installation Kit Instructions

C. 

Testing the Maintain Heat Operation

1. 

Replace the front panel (door).

2. 

Turn on the gas supply at the heater.

3. 

Test the heater/pump operation by running them.  

Make sure that all of the pool heaters’s functions 

are working properly.

D. 

 Replacement Kit List

The following table is for your reference. To order 

additional parts, please contact your local distributor.

Parts List for Maintain Heat Relay Kit

Description

Qty

Maintain Heat Relay

1

Wire, Yellow (ground)

1

Wire, Orange

1

Screw #10-5/8"

2

Instructions

1

3.  Pool Mode - Maintain Heat

If connected, the Maintain Heat mode allows the heater 

to monitor the temperature of the water 24 hours a day 

by turning the pool pump on and sampling the water 

temperature. When the water temperature drops below 

the programmed temperature set point, the control will 

start the heater.

To operate in pool mode with the Maintain Heat feature, 

press 

POOL

, then press 

MENU

, press the 

Down

 button 

until 

MAINTAIN POOL HEAT

 is displayed, press the 

MENU

 button. 

The associated left green LED indicator will light and 

the unit will display 

SET:XXX°. 

Change the temperature 

set point by pressing the 

Up

 or 

Down

 button until the 

desired set point is displayed. After five (5) seconds of 

inactivity, the new set point is stored in memory.

4.  Spa Mode - Maintain Heat

If connected, the Maintain Heat mode allows the heater 

to monitor the temperature of the water 24 hours a day.

When the water temperature drops below the 

programmed temperature set point, the control will start 

the heater.

To operate in spa mode with the Maintain Heat feature, 

press 

SPA

, then press 

MENU

, press the 

Down

 button 

until 

MAINTAIN SPA HEAT

 is displayed, press the 

MENU

 button. The associated left green LED indicator 

will light and the unit will display 

SET:XXX°. 

Change 

the temperature set point by pressing the 

Up

 or 

Down

 

button until the desired set point is displayed. After five 

(5) seconds of inactivity, the new set point is stored in 

memory.