Page 13
ENGLISH
Installation and Operation Manual
|
Jandy® Legacy™ Model LRZE Pool/Spa Heater by Zodiac®
3.2.2 indoor and outdoor Shelter
installations
WaRninG
Vent pipe diameter must be as required by the
National fuel Gas Code Z223.1 or the Canadian
Installation Codes for Gas Appliances CAN/CSA-
B149.1. Undersized pipe can result in inadequate
venting and oversize pipe can result in vent con-
densation. In either case the result can be release
of combustion products to the indoors. This can
cause serious injury or death by carbon monoxide
poisoning or asphyxiation.
aVeRtiSSeMent
Le diamètre des tuyaux de ventilation doit répondre
aux exigences du
National Fuel Gas Code
Z223.1
ou du code canadien des installations des appareils
à gaz CAN/CSA B149.1. Des tuyaux trop petits
risquent d’entraîner une ventilation inadéquate et
des tuyaux trop gros risquent de provoquer une
condensation dans les tuyaux. Dans un cas comme
dans l’autre, des produits de combustion risquent
de s’échapper dans le bâtiment et causer des
blessures graves ou l’asphyxie par le monoxyde de
carbone.
All indoor installations and outdoor shelter
installations require a factory approved draft hood. The
draft hood must be installed without modification. All
vent installations must be made in accordance with all
local, state or provincial codes and with:
1. The National Fuel Gas Code, ANSI Z223.1
(NFPA 54), latest edition; pay particular
attention to the chapter addressing "Venting of
Equipment". Applicable provisions of additional
applicable local building codes may also need to
be followed.
WaRninG
Do not store any chemicals, cleaners, or other
corrosive material near combustion air openings
or in the room. Avoid locating appliance vents in
the vicinity of combustion air openings. Failure
to prevent corrosive materials from mixing with
combustion air can result in reduced heater life
and unsafe heater operation.
aVeRtiSSeMent
Ne pas entreposer ni utiliser d'essence ni d'autres
vapeurs ou liquides inflammables à proximité de
cet appareil ou de tout autre appareil.
3.2
Vent Pipe Sizing and General
installation
3.2.1 outdoor installations
For outdoor installations, exhaust venting
considerations will determine the placement of the
heater, see Section 2.3.4. If the heater cannot be
placed so as to meet the requirements stated in Section
2.3.4, a vent pipe and cap may be added to the heater
to move the exhaust vent opening to a position that
complies with the requirements.
When the heater is installed in areas of high
wind or when unavoidably installed near a vertical
obstruction where downdrafting may occur, it may be
desirable to add a vent cap directly to the top of the
heater.
In all cases, vent pipes and caps must be of the
same diameter as the exhaust outlet of the heater.
Approved vent caps may be obtained through your
Jandy distributor.
3)
notes:
1. Use approved
roof jack.
Figure 5. indoor installation Venting (uSa), or outdoor Shelter (canada)