Section 1. Safety Information
1.1 Important
Safety
Warning
1. Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment of the clamp, or
any other service of the circulating system; (A)
turn the pump
off
and shut off any automatic controls to ensure
the system is not inadvertently started during servicing; (B) open the air release valve; (C) wait until all pressure
is relieved (air will have stopped fl owing from the air release valve).
2. Whenever installing the fi lter clamp
follow Section 3.4
of this manual
, "Clamp Installation".
3. Once service on the circulation system is complete,
follow Section 4
of this manual
, "Start-up and
Operation"
.
4. Maintain circulation system properly. Replace worn or damaged parts immediately.
5. Be sure that the fi lter is properly mounted and positioned according to these installation instructions.
6. Do not pressure test above 50 PSI. Pressure testing must be done by a trained pool professional.
SAVE THESE INSTRUCTIONS.
ATTENTION INSTALLER:
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equip ment.
1.2 General Safety Instructions
WARNING
NEVER OPERATE OR TEST THE FIL TER SYSTEM AT MORE THAN 50 PSI.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE
CIRCULATING SYSTEM, i.e., FILTER, PUMP, VALVE(S), CLAMP, ETC. IS SERVICED,
AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED WHEN THE SYSTEM IS
RESTARTED. PRESSURIZED AIR CAN CAUSE THE FILTER LID TO BE BLOWN OFF
WHICH CAN RESULT IN DEATH, SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE.
TO AVOID THIS PO TEN TIAL HAZ ARD, FOL LOW ALL OF THE IN STRUC TIONS IN THIS
MAN U AL.