Jandy CS100 Скачать руководство пользователя страница 7

Page

Cartridge Filters - CS Series Filter

Never exceed the manufacturer's maximum 

recommended filter flow rates.

5.  For best efficiency use the fewest possible number 

of fittings. This will prevent a restriction of the 

water flow.

6.  Make all plumbing connections in accordance with 

local plumbing and building codes. Filter unions 

are provided with an o-ring seal. Use silicone 

based lubricants on the o-rings to avoid damage. 

Do not use pipe joint compound, glue or solvent 

on union threads.

7.  Keep piping tight and free of leaks. Pump suction 

line leaks may cause air to be entrapped in filter 

tank or loss of prime at the pump. Pump discharge 

line leaks may show up as equipment pad leaks or 

air being discharged through the return lines.

8.  Support the inlet/outlet pipes independently to 

prevent any undue strains.

9.  Place the union nut over the pipe and connect 

the pipes to the union tailpieces using PVC 

glue. Do not use teflon tape or pipe dope on any 

union threads. Put the o-ring in the tailpiece and 

assemble the unions to the filter tank.

10.  Drill pilot holes into the equipment pad with a ¼" 

masonry bit. Use the holes in the tank bottom base 

as a guide.

11.  Install ¼ x 2¼" Stainless Steel Tapcon® screws 

and tighten.

3.3  Filter Installation

1.  This filter operates under pressure. When the 

locking ring is properly seated and the filter is 

operated without air in the water system, this filter 

will operate in a safe manner.

2.  If the system can be subjected to higher pressures 

than the maximum working pressure of the lowest 

rated component, install an ASME approved 

automatic Pressure Relief Valve or Pressure 

Regulator in the circulation system.

3.  Place the filter on the concrete pad, lined up with 

the inlet and outlet pipes.

4.  To reduce pressure losses, 2" (minimum) piping 

is recommended for plumbing the system. 

Figure .  Pressure Gauge and Pressure Release 

Assembly

Air Release

Valve

Pressure

Gauge

Pressure

Gauge

Adapter

Figure 5.  Basic Pool/Spa Combination Plumbing

Jandy Heater

Waterfall

Pool Return

Spa Make Up

Spa Return

From Pool Skimmer

From Pool 

Drain

Spa Suction

Jandy Pump

Jandy

Check

Valve

Outlet  

Port

Inlet Port

Jandy Filter

Inlet  

Port

Drain

Содержание CS100

Страница 1: ...ly Improper installation and or operation can create dangerous high pressure which can cause the filter lid to be blown off possibly causing death serious injury or property damage Improper installation and or operation will void the warranty Before installing this product read and follow all warning notices and instructions that accompany this filter Failure to follow warning notices and instruct...

Страница 2: ......

Страница 3: ...6 3 1 Filter Location 6 3 2 Filter Preparation 6 3 3 Filter Installation 7 3 4 Locking Ring Tank Top Assembly Installation 8 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section 5 Filter Disassembly and Assembly 9 5 1 Filter Element Removal 9 Section 6 Maintenance 10 6 1 General Maintenance 10 6 2 Pressure Gauge10 6 3 Cleaning the Filter Cartridge 10 6 4 Breather Tube Ma...

Страница 4: ...ilter pump valve s clamp etc is serviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause the filter lid to be blown off which can result in death serious personal injury or property damage To avoid this potential hazard follow all of the instructions in this manual WARNING To minimize risk of severe injury or death the filter and or pump shoul...

Страница 5: ...f water in your pool two to four times in a 24 hour period 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and the pressure gauge are convenient and accessible for the installation and operation of the unit 3 Protect the filter from the weat...

Страница 6: ...nts are damaged notify carrier immediately 2 Carefully remove the accessory package Remove the filter tank from the carton 3 A visual inspection of all parts should be made now See parts list in Section 9 4 Install the pressure gauge and adapter assembly to the threaded hole marked Pressure Gauge at the top of the filter see Fig 4 5 Install the air release valve into the threaded opening marked Ai...

Страница 7: ... o ring in the tailpiece and assemble the unions to the filter tank 10 Drill pilot holes into the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 3 Filter Installation 1 This filter operates under pressure When the locking ring is properly seated and the filter is operated without air in the water system t...

Страница 8: ...nal Start up 1 Turn off the filter pump and switch off the circuit breaker to the pump motor 2 Check that the filter drain cap and nut are in place and tight 3 Check that the tank locking ring is properly seated and tight 4 Open the pump hair lint pot lid and fill the pump basket with water to prime the system Replace the pump lid You may have to do this a few times on new and seasonal start ups 5...

Страница 9: ...y pushing on the locking tab and turning the lock ring counterclockwise 5 Remove the top of the filter Inspect the tank o ring for damage Clean or replace the o ring as necessary 6 Remove the filter element from the tank bottom and clean or replace as necessary 7 Place the new or cleaned filter element into the tank bottom 8 Use a Silicone based lubricant on the new or cleaned o ring and place the...

Страница 10: ...d below pool level close any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Open the filter tank drain When the filter tank has drained close the drain Plade it upright in a area suitable for washing 5 Open filter tank and remove cartridge element see Section 5 1 Filter Element Removal Place it upright in...

Страница 11: ...ure gauge to be sure that the pressure does not exceed 50 psi If the pressure approaches 50 psi immediately turn the pump off and clean the filter cartridges If the pressure remains high after cleaning the filter refer to the troubleshooting guide Section 8 for possible causes and solutions Section 7 Winterizing 1 Turn off the filter pump and switch off the circuit breaker to the pump motor 2 Open...

Страница 12: ...tage Check and clean strainer baskets Check all connections between pool intake and pump Check all lines for debris or partially closed valves Clean or replace filter cartridge per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorr...

Страница 13: ...50 R0462300 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 7 Bottom Housing Assembly R0462900 8 Pressure Gauge 0 60 psi R0556900 9 Pressure Gauge Adapter R0557100 10 Air Release Valve R0557200 11 O Ring Set R0466300 Section 9 Parts List and Exploded View 9 1 Jandy Cartridge Filter CS Series 9 2...

Страница 14: ...Page 14 Section 10 Head Loss Curves 10 1 Jandy Cartridge Filter CS Series 0 00 0 50 1 00 1 50 2 00 2 50 3 00 3 50 4 00 0 30 60 90 120 150 FLOW RATE GPM CS100 CS150 DESIGN HEAD LOSS PSI ...

Страница 15: ...Page 15 Cartridge Filters CS Series Filter NOTES ...

Страница 16: ... non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer 9 Overheating incorrect wire runs improper electrical supply collateral damage caused by failure of O Rings DE grids or cartridge elem...

Отзывы: