Jandy AquaPure Скачать руководство пользователя страница 27

SERVICE CODE FLOW CHARTS 

Inspection, Voltage, & Current Tests on pages 17-23. 

Code 

171

Yes

Replace PIB.

Restart system. Wait for 
system diagnostics. 

(Approximately 5 minutes).

Is the 

171 code still present?

No

System is working 
correctly.

Replace the PIB.

Yes

No 

Code combinations 
of

171 & 189 

or 

171 & 190

?

No 

No   

Is the “Cell On” or 
“Cell Reversing” light 
on?

Replace PIB.

Confirm unit is set 
to 100% 
production, the 
“Flow” light is lit 
and the salinity is 
within its proper 
range. Replace 
the PIB.

Yes

Remove Cell and 
visually check calcium 
build up and or debris. Is 
the cell clean?

Clean the cell with 4 parts water and 1 
part muriatic acid. Rinse with fresh 
water when done.

No Code = System 
Operating Normally
Different Code = Proceed to 
that code.

Yes

Yes

No

No

Replace the PIB.

Reinstall and restart the unit. Wait for 
system diagnostics. 

(Approximately 5 minutes).

Does the system show the same 
service code?

Conduct transformer voltage test and PIB DC 
voltage tests. Are the voltages correct?

Yes

Yes

No

Visually check the DC cell cord 
and outside of cell. Are they 
connected loosely together or are 
there signs of damage?

- Loose connection = 
Reconnect firmly.
- Damaged cell or cord = 
Replace cell and cord. 
Next, Restart the unit and 
wait for system diagnostics. 

(Approximately 5 minutes).

Conduct the transformer 
voltage tests. Are the 
voltages correct?

Visually inspect sensor cable and 
check for proper plumbing 
installation. Are these good?

Damaged Cable = Replace sensor.
Incorrect Installation = Plumb correctly.

Remove and 
clean sensor.

Yes

No

No Code = System 
Operating Normally
Different Code = Proceed to 
that code.

Yes

No

Conduct a sensor 
reading test. Does it 
pass the test?

Replace the flow sensor.

Replace the PIB.

Yes

No 

Code 

172

or combinations of 

172 & 180,

or

172 & 181, 

or 

172 & 183, 

or 

172 & 184, 

or

172 & 185, 

or 

172 & 186

?

Yes

No

115

230

Check Incoming Power. Is 
the input voltage 115, or 230 
VAC?

Is the unit still factory 
wired for 230 VAC?

Rewire unit for 115 
VAC.

Reinstall and restart the unit. Wait for 
system diagnostics. 

(Approximately 5 minutes).

Does the system show the same 
service code?

No

No 

Restart the unit. Wait for system diagnostics. 

(Approximately 5 minutes).

Does the system show the 

same service code?

Replace PIB

Replace Transformer

Yes 

No 

Conduct all voltage tests on the PIB. Are either or both voltages low?

No Code = System 
Operating Normally
Different Code = Proceed to 
that code.

Yes 

Code combinations of 

173 & 187, 

or

173 & 188

?

27 

Содержание AquaPure

Страница 1: ...Jandy AquaPure PureLink Nature Fusion Soft Workbook...

Страница 2: ...atives________________________________________ ext _________ __________________________________________________________ ext _________ __________________________________________________________ ext ___...

Страница 3: ...TRANSFORMER VOLTAGE 17 18 POWER INTERFACE BOARD PIB DC VOLTAGE 19 SENSOR INSPECTION 20 PIB SENSOR READINGS TEST 21 CELL INSPECTION 22 CELL VOLTAGE AND CURRENT 23 SERVICE CODE 24 SERVICE CODE FLOW CHA...

Страница 4: ...Still Available Fusion MODEL FUSIONM Finished Goods Part Numbers Chlorine Generators 6613AP PLC1400 Power Pack Model 6614AP L Sub Panel Power Center PureLink for AL RS PDA 6613AP Standard Power Cente...

Страница 5: ...dizes soil dirt algae organic material leaving 7 Hydrochloric Acid Sodium Hydroxide 8 Salt Recycled Liquid Chlorine Salt NaCl 5 Notes __________________________________________________________________...

Страница 6: ...1 4 A B DBI INTERFACE Mechanical Sensor ENB DIS FLOW SENSOR H Temp R Temp Salinity 1 Amp FUSE Salinity 2 8 R Temp 75 H Temp 91 TEST POINTS 19 VAC VAC 1 VAC 2 120 mVDC 65 VAC 75 VAC 15 Amp FUSE 24 VDC...

Страница 7: ...artridge NATURE FUSION SOFT KITS 16 CORDS FSOFT700 Up to 12 000 Gallons FSOFT1400 Up to 40 000 Gallons NATURE CARTRIDGES W28000 Single Cartridge for FSOFT700 W26000 4 Pack of Cartridges for FSOFT700 W...

Страница 8: ...per inhibits algae growth regularly sold as algaecides Silver known bactericide used for thousands of years to bacteria in water milk and on skin Porous Alumina releases silver and copper assists in t...

Страница 9: ...uld be pointed down to prevent air entrapment which could cause false readings 3 Port Cell and Sensor OK Plumbing The 3 Port Cell can be located so the sensor is mounted to the side of the cell 3 Port...

Страница 10: ...gs 3 Port Cell and Sensor Wrong Plumbing If the 3 Port Cell is plumbed as shown the sensor may provide inaccurate readings 10 Notes ____________________________________________________________________...

Страница 11: ...e plumbed on the inlet side of the Nature Fusion 11 Notes _____________________________________________________________________ _____________________________________________________________________ __...

Страница 12: ...ge Cable Extension wires from the PIB Cell Low Voltage Cable Black White Wire Green Wire Black Wire White Wire Green Wire Cell Low Voltage Cable Extension Cell Low Voltage Cable Original New Black Whi...

Страница 13: ...m on the equipment pad Connected to load side of time clock or relay All electrical equipment connected by bond wire Versa Plumb Nature Fusion Soft Cell should be the last item on the equipment pad Co...

Страница 14: ...pool increases the killing power of chlorine decreases At a pH of 6 0 we ll get 96 or so of the potential out of each lb of chlorine but at what cost S uch a low pH would wreck havoc on all of the sur...

Страница 15: ...4 000 28 000 30 000 0 0 gpl 250 lbs 350 lbs 450 lbs 500 lbs 600 lbs 700 lbs 750 lbs 1 0 gpl 165 lbs 230 lbs 300 lbs 330 lbs 400 lbs 460 lbs 495 lbs 1 5 gpl 125 lbs 175 lbs 225 lbs 250 lbs 300 lbs 350...

Страница 16: ...is less than 51 degrees F BO boost cycle has been activated Cancel by holding the POOL TEMPERATURE button down for 10 seconds EC the unit is being controlled by an external controller or ORP device J...

Страница 17: ...VAC 2 120 mVDC 65 VAC 75 VAC 15 Amp FUSE 24 VDC 5 VDC COMMON GROUN D HEATER RESTING CELL ON FLOW SERVIC E ORP LOW SALT 12 VDC First Test Set the meter to 200 ACV or higher Put the leads on the 75 VAC...

Страница 18: ...1 VAC 2 of the 19 VAC test points The voltage should be between 17 to 24 If no voltage is present check 1 Amp Fuse on PIB If the voltage is outside the above range replace the Transformer 18 Notes __...

Страница 19: ...ON FLOW SERVIC E ORP LOW SALT 12 VDC This test confirms that the Power Inter face Board PIB is taking the AC Volt age from the Transformer and converting it to DC Voltage 19 VAC VAC 1 VAC 2 24 VDC 5...

Страница 20: ...done 3 Thoroughly rinse the Flow Temp Salinity Sensor with clean tap water Replace and resume normal operation 4 Turn power off and back on to re calibrate and reset Flow Temp Salinity Sensor PROBLEM...

Страница 21: ...nsor must be disconnected for these 3 Tests A B C D 2 8gpl A B C D 91 F FLOW SENSOR H Temp R Temp Salinity Salinity 2 8 R Temp 75 H Temp 91 19 VAC VAC 1 VAC 2 24 VDC 5 VDC 12 VDC FLOW SENSOR H Temp R...

Страница 22: ...the center terminal and the other probe to either outside termi nal Make certain cable stays in contact with terminals Turn on power and wait for control to call for chlorine production With the cell...

Страница 23: ...ll and that the cell has the proper current passing between plates The Chlorine Generator has to be set to 100 and producing chlorine to perform these tests DCV W 2000K 200K 20K 2K hFE 2 20 200 1000 2...

Страница 24: ...tion or very low salinity LEVEL 2 180 Heated sensor element not heating generates 172 code 181 Flow sensor temperature sensor failure generates 172 code Flow sensor service 182 Salinity Sensor sees le...

Страница 25: ...ts or Confirm proper salinity and check for Metals in the water and possible shorts between the plates posts on the cell and inside the cord Yes Yes Yes Yes No No No No Code 124 Remove the Cord from t...

Страница 26: ...cell or cord Replace cell and cord Next Restart the unit and wait for system diagnostics Approximately 5 minutes Reinstall and restart the unit Wait for system diagnostics Approximately 5 minutes Doe...

Страница 27: ...Loose connection Reconnect firmly Damaged cell or cord Replace cell and cord Next Restart the unit and wait for system diagnostics Approximately 5 minutes Conduct the transformer voltage tests Are th...

Страница 28: ...vel with another accurate salt testing method Do the salinity tests match 1 GPL or 100 ppm Add or dilute salt accordingly Let salt mix for 24 hours and retest levels Yes No Yes Visually inspect sensor...

Страница 29: ...ell cord and restart the unit Wait for system diagnostics and retest Approximately 5 minutes DCV W 2000K 200K 20K 2K 200 hFE 2000 2 20 200 1000 200 750 PNP NPN OFF 200m 20m 200m 10A 200 ACV DCA 120 DC...

Страница 30: ...200m DCA 20m 200m 10A 200 ACV 21 30 Flow Sensor R Temp H Temp Salinity Disconnect Flow Sensor Before Using Test Switches Salinity 2 8 GPL R Temp 75 F H Temp 91 F Test Point Common A to C 21 VAC K to H...

Страница 31: ...cle in Progress Add Salt Salinity Should be 3 0 3 5 Grams Liter Service Refer to Manual To Silence Audible Service Alarm Press and Hold Salinity Button 5 Seconds Display side of AquaPure Upper right s...

Страница 32: ...32 AP Nature Fusion Soft 7 2010 Final Zodiac Pool Systems Inc 800 822 7933...

Отзывы: