9.1 Ordering 

Information

To order or purchase parts for the AE-Ti models of heat pumps, contact your nearest Air Energy

 dealer or 

distributor.  If they cannot supply you with what you need, contact Jandy International Service Department located at: 
2735 NW 63 Court, Fort Lauderdale, Florida, 33309 - USA, Tel: 1-954-970-4800.

Section 9.  Replacement Parts

9.2 Air 

Energy

 AE-Ti Heat Pumps Parts List

Key  

 

Order

No.  Description 

Model No. 

Part No.

Top Enclosure, Jacket 

200, 300 

R3004701

Top Enclosure, Jacket 

400, 500 

R3004702

2 Service 

Access 

Panel 

All 

R3004900

Control, Smoked Cover 

All 

R3007500

Fan Motor, 1/6HP, 208-230VAC 

200, 300 

R3005001

Fan Motor, 1/6HP, 380-420VAC 

200, 300 

R3005002

Fan Motor, 1/2HP, 208-230VAC 

400, 500 

R3005003

Fan Motor, 1/2HP, 380-420VAC 

400, 500 

R3005004

5 Contactor 

All 

R3005100

6 Transformer, 

208-230VAC 

All 

R3005201

Transformer, 380-420VAC 

300, 400, 500  R3005202

Water Press Switch 

All 

R3005300

Capacitor, Fan Motor, 3/370 MFD 

200, 300 

R3005401

Capacitor, Fan Motor, 5/370 MFD 

300 

R3005402

Capacitor, Fan Motor, 7.5/370 MFD 

400, 500 

R3005403

Capacitor, Fan Motor, 10/370 MFD 

400, 500 

R3005404

Capacitor, Compressor, 45/370 

200 

R3005501

Capacitor, Compressor, 55/440 

400, 500 

R3005502

Capacitor, Compressor, 30/370 

300 

R3005503

10 Controller 

Assy, 

Universal 

All 

R3005600

11  Refrigerant HP Switch 

All 

R3005700

12  Refrigerant LP Switch (Heat Only) 

All 

R3005801

12  Refrigerant LP Switch (Heat/Cool) 

400, 500 

R3005802

13  Wire Harness Kit (Not Shown) 

All 

R3007600

14  Fan Blade Set 

200, 300 

R3005901

14  Fan Blade Set 

400, 500 

R3005902

15  Fan Guard 

200, 300 

R3006001

15  Fan Guard 

400, 500 

R3006002

16 Plumbing 

Tree/Bypass 

Assy 

200, 

300 

R3006101

16 Plumbing 

Tree/Bypass 

Assy 

400 

R3006102

16 Plumbing 

Tree/Bypass 

Assy 

500 

R3006103

17  2” PVC Union Set 

All 

R3006200

18  Evaporator Coil/Guard 

200, 300 

R3006301

18 Evaporator 

Coil/Guard 

400 

R3006302

18 Evaporator 

Coil/Guard 

500 

R3006303

19  Heat Exchanger Drain Kit (Not Shown) 

All 

R3006400

20  Heat Exchanger, Ti50 

200, 300 

R3006501

20 Heat 

Exchanger, 

Ti85 

400 

R3006502

20 Heat 

Exchanger, 

Ti105-R.2 

500 

R3006503

21  Compressor, 24K, 1 Phase 

200 

R3006601

21  Compressor, 37K, 1 Phase 

300 

R3006602

21  Compressor, 37K, 3 Phase 

300 

R3006603

21  Compressor, 45K, 1 Phase 

400 

R3006604

21  Compressor, 45K, 3 Phase 

400 

R3006605

21  Compressor, 68K, 1 Phase 

500 

R3006606

21  Compressor, 68K, 3 Phase 

500 

R3006607

22  Thermal Expansion Valve (TXV) (Not Shown) 

200, 300, 400  R3006701

22  Thermal Expansion Valve (TXV) (Not Shown) 

500 

R3006702

23 Water 

Temperature 

Sensor 

All 

R3006800

24 Air 

Temperature 

Sensor 

All 

R3006900

25  3 Phase Monitor (3 Phase Models Only) (Not Shown) 

300, 400, 500  R3007000

26  Reversing Valve (Not Shown) 

400, 500 

R3007100

27  Cover, Junction Box 

All 

R3007200

28  Filter Drier, Heat Only  

200, 300 

R3007301

28  Filter Drier, Heat Only 

400, 500 

R3007302

28  Filter Drier, Heat/Cool 

400, 500 

R3007303

29  Hardware Kit (Heat/Cool) (Not Shown) 

All 

R3007400

30  Main Power PCB, Universal 

All 

R3007700

31 Fan 

Relay 

All 

R3008600

Содержание Air Energy AE-Ti

Страница 1: ...ed electrician in accordance with applicable national and local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to pool or spa...

Страница 2: ......

Страница 3: ...onnection to a Remote Pool Off Spa Selector 3 Wire Connection 16 4 5 1 1 Install the Remote Pool Off Spa Selector 16 4 5 1 2 Configure the Control Panel 21 4 5 2 Two Wire Connection to an AquaLink RS...

Страница 4: ...ink RS to AE Ti Heat Pump Chiller Wiring 22 Figure 17 AE Ti Heat Pump Connection to Power Center 23 Figure 18 Main Control Panel 24 Figure 19 Winterizing the AE Ti Heat Pump 29 Figure 20 Heat Pump Ope...

Страница 5: ......

Страница 6: ......

Страница 7: ...thermometer before entering a spa or hot tub Temperature controls may vary by as much as 1C 1F 5 Persons with a medical history of heart disease diabetes circulatory or blood pressure problems should...

Страница 8: ...e summertime You can reduce heat pump usage due to warmer air temperatures 3 During the winter or when on vacation for longer than a week turn off the heat pump 4 Find the proper setting on the heat p...

Страница 9: ...of sight of the heat pump 5 Watertight conduit to run the electrical supply line 1 6 2 Recommended Materials for Installations Air Energy recommends installing isolation valves on the inlet and outle...

Страница 10: ...et at 285 PSI REFRIGERANT LOW PRESSURE ALARM 2 1 bar reset at 5 1 bar 30 PSI reset at 74 PSI Reversible 15 PSI reset at 40 PSI LOW WATER FLOW ALARM 6 m3 h MAXIMUM HEIGHT BELOW WATER LEVEL 3 5 meters b...

Страница 11: ...per 50 cm inch per foot toward the compressor end front of the heat pump Pitch slab from back to front 1 cm per 50 cm inch per foot maximum and level from side to side Section 2 Installation Instruct...

Страница 12: ...that no part of the tubing or hose may be above the level of the drain hole in the base of the heat pump 2 2 5 Outdoor Installations CAUTION When pool equipment is located below the pool surface a lea...

Страница 13: ...water loss or flooding or the damage caused by either occurrence 3 2 Water Connections at Heat Pump Shipping plugs have been installed in the water inlet and outlet ports of the heat pump at the facto...

Страница 14: ...ool Shared Filtration Systems Filter Spa Pool Figure 3 Shared Filtration System Filtration Pump 3 way valve Heat Pump to Heat Spa Spa Pool Heat Pump to Heat Pool Spa Pool Independent Filtration System...

Страница 15: ...pump installations must be done in parallel see Figures 6 through 9 An equal flow of water to each heat pump is important for optimum operation Figure 5 Plumbing For Heating System Combinations Heater...

Страница 16: ...imum 50 mm pvc pipe OPTIONAL 50 mm Gate Valve Bypass 50 mm pvc 50 mm pvc Figure 7 Four Heat Pump Plumbing Layout Minimum 75 mm pvc pipe Pool pump 75 mm pvc pipe 75 mm Gate Valve Bypass To Pool 75 mm p...

Страница 17: ...c Figure 9 Eight Heat Pump Plumbing Layout Dual Headers Extend 41 51 cm past end heater inlet for hydraulic balancing NOTE Gate Valves are required on heater inlets to help system balancing Extend 41...

Страница 18: ...st be made exactly as shown in the wiring diagram found on the inside of the heat pump access compartment See Figure 10 for single phase electrical wiring and Figure 11 for 3 phase electrical wiring S...

Страница 19: ...Page 17 Figure 10 AE Ti Single Phase Electrical Supply Wiring Diagram TO FILTRATION PUMP ELECTRICAL BOARD SEE FIGURE 13...

Страница 20: ...LA DEFINICI N DE LOS S MBOLOS EN EL MANUAL DE INSTA LACI N Y OPERACI N BR BK BL Y W Y OUT Y C THREE PHASE LINE VOLTAGE MONITOR L1 L2 L3 Y Y R R L 2 BK BK W BK BK BK BK R W R BK R BL W Y Y W W W BL JVA...

Страница 21: ...H POOL SPA GROUND CONNECTION WATER PRESSURE SWITCH OPTIONAL HEAT COOL REVERSING VALVE 24 VAC TRANSFORMER COMPRESSOR CAPACITOR SYMBOL DEFINITIONS TERMINAL LUG EARTH TERMINAL INTERNATIONAL LANGUAGES HEA...

Страница 22: ...CONNECTOR FOR HIGH VOLTAGE WIRES CONNECTOR FOR LOW VOLTAGE WIRES SERVICE ACCESS PANEL 4 SCREWS Figure 13 Example of wiring to the Time Clock for enabling the MAINTAIN TEMP feature On Off Contactor Fi...

Страница 23: ...Remote TSTAT Connection 2 Wire Connection 4 5 2 2 Install the Remote TSTAT or AquaLink RS 1 Turn off the power to both the pool spa control system and the heat pump unit 2 Remove the screws that atta...

Страница 24: ...X 2 A U X 3 A U X 4 A U X 5 A U X 6 A U X 7 RS6 RS8 ONLY RS8 ONLY HEATER SOLAR POOL MODE SPA MODE SPA DRAIN SPA FILL AUTO 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 4 3 2 1 4 3 2 1 S1 S2 OFF ON OFF ON 1 2 3 4 5...

Страница 25: ...s heat pump if any part has been under water Immediately call a qualified service technician to inspect the heater and replace any part of the control system which has been under water ATTENTION After...

Страница 26: ...nitor the temperature of the water 24 hours a day by turning the pool pump on and sampling the water temperature When the water temperature drops below the programmed temperature set point the control...

Страница 27: ...guage press the MENU button to select the language Press POOL or SPA to exit the User Setup mode When the water temperature drops below the programmed temperature set point the control will start the...

Страница 28: ...Use the Up or Down button to scroll to display SELECT DISPLAY LIGHT LIGHT OFF this option allows the display light to turn off press the MENU button to select Use the Up or Down button to scroll to d...

Страница 29: ...mb wheel on the water pressure switch in a clockwise direction until NO FLOW is displayed on the control and the heat pump shuts down 8 Check the setting of the water pressure switch by starting and s...

Страница 30: ...increases Check the following at regular intervals to ensure proper condensate drainage 1 Visually inspect and clear the bottom drain ports of any debris that could clog the ports 2 Ensure that conde...

Страница 31: ...r Energy Heat Pump is one of the most efficient ways to heat a pool or spa The heat pump transfers heat from the outside air to the pool or spa water by means of an internal heat exchanger See Figure...

Страница 32: ...NU POOL and SPA button for 5 seconds NOTE The display will revert back to OFF after one minute since the last key press 3 The maintain temperature delay is used when MAINTAIN TEMP is connected This fe...

Страница 33: ...button The 2 C 35 F default mode appears use the Up or Down button to scroll to display the desired temperature adjustment press the MENU button to select Press POOL or SPA to exit the Service Setup m...

Страница 34: ...mode 2 To enter the Service Setup mode press and hold the MENU POOL and SPA button for 5 seconds NOTE The display will revert back to OFF after one minute since the last key press 3 This feature shows...

Страница 35: ...porarily turn off all fountains and water falls that bypass the heat pump water inlet If this does not correct the problem call for service Heat pump does not run and control board display shows FAULT...

Страница 36: ...e there could be safety risks for anyone in the water The water thermostat will read this temperature and the control will shut off the heat pump unless it is in CHILLER mode This feature also remains...

Страница 37: ...14 1 17 0 Amps 3 Ph 6 9 7 2 7 5 8 1 AE500TI Refrigerant High Pressure 15 4 224 17 1 248 15 7 228 19 2 275 Refrigerant Low Pressure 3 2 46 3 7 54 4 3 62 6 8 98 Amps 1 Ph 22 1 24 1 22 6 26 1 Amps 3 Ph 9...

Страница 38: ...nly All R3005801 12 Refrigerant LP Switch Heat Cool 400 500 R3005802 13 Wire Harness Kit Not Shown All R3007600 14 Fan Blade Set 200 300 R3005901 14 Fan Blade Set 400 500 R3005902 15 Fan Guard 200 300...

Страница 39: ...8 23 5 17 B 21 18 A 27 10 20 28 4 14 1 3 15 24 12 11 DETAIL B DETAIL A These pressure switches are installed in the refrigerant line near the compressor R E D W I R E B L U E W I R E 16 Y E L L O W W...

Страница 40: ...actices and the manufacturer s installation instructions 2 damage malfunctions or failures resulting from negligence and or abuse 3 if the product is modified in any way or non factory authorized acce...

Отзывы: