Page 32
7.3.8
Water Temperature Calibration
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature adjusts the heat pump water
temperature sensor. To select Water Temperature
Calibration, use the
Up
or
Down
button to scroll
through to display
WATER TEMP CAL
. Press the
MENU
button. The
0°F
(default mode) appears,
use the
Up
or
Down
button to scroll to display the
desired temperature adjustment, press the
MENU
button to select
.
Press
POOL
or
SPA
to exit the
Service Setup mode.
7.3.9
Water Temperature Differential
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature sets the temperature differential the
heat pump will turn back on. To select Water
Temperature Differential, use the
Up
or
Down
button to scroll through to display
WATER
TEMP DIFF
. Press the
MENU
button. The
3°F
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired temperature
adjustment, press the
MENU
button to select
.
Press
POOL
or
SPA
to exit the Service Setup
mode.
7.3.10 Delay On Make
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature determines the amount of time the
heat pump waits before turning on the compressor.
To select Delay On Make, use the
Up
or
Down
button to scroll through to display
DELAY ON
MAKE
. Press the
MENU
button. The
5 MINS
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired amount
of time, press the
MENU
button to select
.
The
remaining time is displayed while counting down.
Press
POOL
or
SPA
to exit the Service Setup
mode.