background image

Page 31 

ENGLISH

  

 

Jandy

®

 Pro Series, JXi

 Gas-Fired Pool & Spa Heater   

|

   Installation & Operation Manual

Par

t Number

:   H0415400 RE

V B

D

escr
iption:  JXi Hea

ter Ligh

ting I

nstruc

tions f

or inside lid panel

Siz

e: 

12 x 7.5 inches  

Color

Pan

tone R

ed 186 C, Black

 

die line does not print

H0415400 REV C

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

1. STOP! Read the safety information above on

this label.

2.* Set the thermostat to lowest setting and turn

appliance switch to OFF.

3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition

device which automatically lights the heater.

Do not try to light the burners by hand.

5. Remove the top panel.
6. Turn gas control switch to OFF position
7. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow "B" in the

safety information above on this label. If you

don't smell gas, go to next step.

8. Turn gas control switch to ON position.

9. Replace the top panel.
10. Turn on all electric power to appliance.
11.* Set thermostat to desired setting and switch

appliance from OFF to either POOL or

SPA.

12. If the appliance will not operate, check that

the filter pump is on, the filter is clean and

water is flowing to the pool. Otherwise,

follow the instructions "To Turn Gas 

Off” and call your service technician

or gas supplier.

TO TURN 

GAS OFF 

WARNING

If you do not follow these instructions exactly, a fire or explosion may result, 

causing property damage, personal injury, or death.

(A)  This appliance does not have a pilot light. It is equipped with an ignition device which automatically lights the heater. Do NOT try to light the 

burners by hand.

(B)  BEFORE OPERATING, smell all around the appliance for gas. Be sure to smell next to the floor because some gas is heavier than air and 

will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

- Do not try to light any appliance.

- Do not touch any electric switch; do not use any phone in your building.

- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the Fire Department.

(C)  Use only your hand to activate the gas control switch. Never use tools. If the switch will not move by hand, do not try to repair it. Call a 

qualified service technician. Force or attempted repair may result in fire or explosion.

(D)  Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to 

replace any part of the control system which has been under water. 

(1)  

*

 Set the thermostat to 

lowest setting and switch 

appliance to OFF.

(2)  Turn off all electrical 

power to the appliance if 

service is to be performed.

(3)  Turn gas control switch 

to OFF positition.

(4)  Replace top panel. 

See manual for details of 

operation and thermostat control.  

POUR VOTRE PROPRE SÉCURITÉ LISEZ CECI AVANT D’UTILISER LE CHAUFFE-EAU

AVERTISSEMENT

Si vous ne suivez pas ce directives à la lettre, un incendie ou explosion peut en 

être le resultat. Ceci causera des dommages aux biens des blessures personnelles 

ou la mort.

(A)  Cet appareil n’est pas muni d’une veilleuse. Il est muni d’un appareil d’allumage qui déclenche le chauffe-eau automatiquement. Ne pas 

esssayer d’allumer les brûleurs à la main.

(B)  AVANT DE METTRE EN MARCHE, assurez-vous qu’il n’y a aucune odeur de gaz autour de l’appareil. Assurez-vous qu’il n’y a aucune 

odeur de gaz près du plancher, car certains gaz sont plus lourds que l’air et on pour effet de s’accumuler au plancher.

QUOI FAIRE S’IL Y A UNE ODEUR DE GAZ

- Ne pas essayer de mettre en marche quelque appareil que ce soit.

- Ne touchez à aucun interrrupteur électrique. Ne pas faire usage d’un appareil téléphonique dan votre édifice.

- Contactez immediatement à partir du téléphone d’un voisin votre fournisseur de gaz. Suivez ses directives

- Si vous ne pouvez pas joindre avec votre fournisseur de gaz, appelez le service des incendies.

(C)  Utilisez seulement votre main pour opérer le bouton de la commande de gaz. Ne jamais utiliser un outil. S’il est impossible d’opérer le 

bouton à la main, n’essayez pas de le réparer. Appelez un technicien de service qualifié. L’utilisation d’une force quelconque peut avoir pour 

résultat un feu ou une explosion.

(D)  Ne pas utiliser cet appareil si une pièce quelconque a ete submergé. Contactez immediatement un technicien qualifié afin de faire examiner 

l’appareil et faire remplacer toute piece du système de contrôle ainsi que toute commande de gaz qui aurait été submergé. 

INTERRUPTION DE 

L’ALIMENTATION 

EN GAZ

(1)  * Règlez le thermostat au 

plus bas et mettre le bouton de 

commande à OFF.

(2)  Interrompez toute alimenta-

tion électrique a l’appareil si on 

doit faire de l’entretien ou 

réparation.

(3)  Tournez l’interrupteur de 

commande de gaz jusqu’à la 

position OFF. 

(4)  Remplacez le panneau 

supérieure. 

* Voir le manuel pour les détails 

concernant l’opération du contrôle de 

thermostat.  

1.

ARRÊTEZ ! Lisez les directives de sécurité ci-dessus sur cette
étiquette.

2.* Réglez le thermostat au plus bas et mettez la commande de

l’appareil à la position   OFF  .

3.

Éteignez toute alimentation électrique de l’appareil.

4.

Cet appareil est muni d’un dispositif d’allumage qui met le
chauffe-eau en marche automatiquement. Ne pas essayer
d’allumer les brûleurs à la main.

5.

Enlevez le panneau supérieure.

 

   

6.

Tournez l’interrupteur de commande de gaz jusqu’à la position ON.

   

     

   

 

   

 

 

   

   

 

7.

Attendez  pendant cinq (5) minutes afin que le gaz se dissipe.
Assurez-vous qu’il n’y a aucune odeur de gaz, même au niveau
du plancher. S’il y a une odeur de gaz ARRÊTEZ-VOUS ! Suivez
l’étape « B » ci-dessus. S’il n’y a pas d’odeur de gaz, procédez à
la prochaine étape.

8.

Tournez le l’interrupteur de commande de gaz jusqu’a la position OFF.

   

   

9.

Replacez le panneau supérieure. 

 

 

10. Mettez l’appareil sous tension.

11.*  Réglez le thermostat comme désiré et tournez le bouton de

commande de la position    OFF   à la position   POOL   ou 
SPA  .

12. Si l’appareil ne se met pas en marche, assurez-vous que la

pompe du filtre fonctionne, que le filtre soit propre et qu’il y a
un débit d’eau vers la piscine.  Autrement suivez les direc-
tives.

 

 

MODE D’EMPLOI

COMMANDE DE
 GAZ À LA 
POSITION “OFF”

GAS CONTROL 
SWITCH IN 
“OFF” POSITION

                             

Figure 29. Lighting and Shutdown Instructions Label on Top Panel

Содержание 200

Страница 1: ...n and or operation can create carbon monoxide gas and flue gases which can cause serious injury property damage or death For indoor installations as an additional measure of safety Zodiac Pool Systems...

Страница 2: ...lve Installation 20 5 8 Auxiliary Components Chlorinators Ozone Generators and Sanitizing Chemicals 21 Section 6 Electrical Connections 21 6 1 General Information 21 6 2 Service Access 23 6 3 Main Pow...

Страница 3: ...thy adult Special caution is recommended for young children 2 The drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subse...

Страница 4: ...ility or Authority Having Jurisdiction AHJ In the absence of local codes refer to the latest edition of the following national codes for installation 1 In the United States the National Fuel Gas Code...

Страница 5: ...r electrical wiring if required Adequate water flow This manual provides the information needed to meet these requirements Review all applications and installation procedures before continuing the ins...

Страница 6: ...per operation of the burner system and cannot be accomplished with common positive pressure gas valves 2 Combustion Blower and Air Orifice The blower pulls air and fuel gas in through their respective...

Страница 7: ...determining the cause and without replacing the limit switch with an exact replacement 9 Air Pressure Switch The air pressure switch monitors the vacuum negative pressure within the blower housing Thi...

Страница 8: ...nts CAUTION When pool equipment is located below the pool surface a leak from any component can cause large scale water loss or flooding Zodiac Pool Systems Inc cannot be responsible for such water lo...

Страница 9: ...he concrete at each of the brackets on each corner of the heater The correct size drill bit is usually provided with the concrete screws when purchased 3 Place a screw in each of the holes and fasten...

Страница 10: ...ndicated is for one of two openings one 12 inches from floor level one 12 inches from ceiling level Model Direct from outside Duct from outside in2 cm2 in2 cm2 200 50 323 100 645 260 65 419 130 839 33...

Страница 11: ...vent Category I installations are vented vertically and terminate at the roof Category III A Category III appliance is a vented appliance that operates with a positive vent static pressure and with a...

Страница 12: ...wall vent connector is required The heater must not be used to support the vent pipe Note that the tables for fan assisted appliances include both maximum and minimum vent loading figures in the NFPFA...

Страница 13: ...M TOP AND BOTTOM Figure 9 Indoor Installation Venting USA or Outdoor Shelter Canada for Category I Figure 10 Side Wall Vent Terminals for Category III US installations Refer to CSA B149 for requiremen...

Страница 14: ...heater especially in certain cold climate installations See Table 3 for recommended vent size and run lengths without elbows For each elbow installed reduce the run length by 12 feet 3 7m Heater Size...

Страница 15: ...at test pressure equal to or less than 1 2 psi 3 5kPa The heater and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at...

Страница 16: ...Do not use an open flame to test for leaks CAUTION Some leak test solutions including soap and water may cause corrosion or stress cracking Rinse the piping with water after testing 8 Test gas offset...

Страница 17: ...ow through the heater Flow rates at less than 30 gpm may cause nuisance operation causing the heater to turn off or damage to the heater 2 Adjust the valve to bring the flow rate within the acceptable...

Страница 18: ...performance and efficiency The sweep elbow also provides the advantage of its exclusive interface with the Zodiac AquaLink RS temperature sensor The sweep elbow may be installed in the top inlet conne...

Страница 19: ...pply to the heater 7 Start the system and check for proper water flow 5 4 Water Pressure Switch Adjustment CAUTION The water pressure switch should be adjusted to turn the heater off when the pump is...

Страница 20: ...er Connections The JXi heater is shipped with water connections on the right side but the top panel can be rotated to adapt to left side water connections This procedure involves turning the heater an...

Страница 21: ...ift the lever with the circulation system running to ensure that water will pass through When the lever is down there should be no leaks from the outlet 5 8 Auxiliary Components Chlorinators Ozone Gen...

Страница 22: ...IR FLOW SWITCH GAS VALVE WATER TEMP SENSOR BL W BK TO PUMP STARTER CONTACTS IF USED TO COMBUSTION AIR LOUVER STARTER IF USED W FUSE R R Y Y O BK Y BK Y O Y BK O BR Y BR Y R BL BK BK BK W BK BL BR Y W...

Страница 23: ...f the 120V power supply has to be connected to the black wire ACH1 on the power distribution board and the Neutral wire of the 120V power supply has to be connected to the red wire ACN1 of the power d...

Страница 24: ...bove ground components be bonded together forming an equipotential bonding grid with a solid copper conductor not smaller than an 8 AWG 6 AWG in Canada The NEC and CEC also require that the equipment...

Страница 25: ...it is recommended that the time clock have its own low voltage Fireman s switch to turn off the heater before turning off the pump The switch should shut off the heater about 15 minutes before the fil...

Страница 26: ...4 A U X 5 A U X 6 A U X 7 RS6 RS8 ONLY RS8 ONLY HEATER SOLAR POOL MODE SPA MODE SPA DRAIN SPA FILL AUTO Connection to Controller RS485 Connectors Spa Side Switch Sensors and Heater Relay Sockets 24 V...

Страница 27: ...Spa mode see section 7 6 Operating the Heater 5 Start the heater see section 7 2 Lighting the Burner 6 When the heater starts confirm there is adequate water flow by touching the outlet header The hea...

Страница 28: ...ON by pressing POOL or SPA and set the temperatures as necessary NOTE If the heater does not start check that the filter pump is ON the filter is clean and that water is flowing to the pool If the hea...

Страница 29: ...Up or Down to toggle between F and C 6 Press MENU to select scale 7 Press POOL or SPA to exit the User Setup mode To Program Display Light to Turn Off Automatically 1 Make sure the control is OFF 2 Pr...

Страница 30: ...ghts and the control unit displays SET with the current temperature setting 5 Press Up or Down to change temperature set point NOTE After 5 seconds of inactivity the new temperature will be stored as...

Страница 31: ...esultat Ceci causera des dommages aux biens des blessures personnelles ou la mort A Cet appareil n est pas muni d une veilleuse Il est muni d un appareil d allumage qui d clenche le chauffe eau automa...

Страница 32: ...the drain plug 2 Uncover the vent grill 3 Make sure power is supplied to the pump 4 Turn on the filter pump and circulate water through the heater for 5 minutes Check for leaks while circulating 5 Tur...

Страница 33: ...interface Temperature control e Vent temperature limit switch f Control circuit fuse g Ignition control h Air pressure switch 5 Inspect the inlet grill at the blower for blockage leakage and corrosio...

Страница 34: ...t properly connect manometer to blower throat and gas valve port to obtain differential Make sure the differential value falls within the specified range for the heater size see Table TBD Not enough h...

Страница 35: ...ature fan failure Air flow restricted at intake or discharge Broken igniter Low gas supply pressure No flame at burners Check tubing and replace if necessary Correct fault or replace fan Replace ignit...

Страница 36: ...valve vent port 2 Connect a shorter hose to the opposite side of the tee to the gas valve vent port 3 Connect the third part of the tee with a hose to the positive side of the manometer 4 Connect a s...

Страница 37: ...dy Pro Series JXi Gas Fired Pool Spa Heater Installation Operation Manual 11 2 JXi Major Components Cabinet See Section 11 3 Electrical System See Section 11 6 Heat System See Section 11 4 Water Syste...

Страница 38: ...592500 R0592500 R0592500 R0592500 3 Heater Base Kit R0592600 R0592600 R0592600 R0592600 4 Front or Back Panel Kit R0592700 R0592700 R0592700 R0592700 5 Side Panel Kit set of 2 Kit R0592900 R0592900 R0...

Страница 39: ...500 4 Combustion Chamber Kit R0590600 R0590600 R0590600 R0590600 5 Combustion Chamber Shelf set of 3 Models 200 260 330 R0590700 R0590700 R0590700 R0590700 6 Combustion Chamber Lid Kit R0590800 R05908...

Страница 40: ...40 ENGLISH Jandy Pro Series JXi Gas Fired Pool Spa Heater Installation Operation Manual 11 4 2 Combustion Chamber Assembly Exploded Parts Diagram 4 3 11 1 9 2 6 8 2 7 10 3 330 260 200 5 7 9 7 8 8 7 8...

Страница 41: ...Intake Orifice Kit R0591302 R0591312 R0591303 R0591313 R0591304 R0591314 R0591305 R0591315 4 Fuel Orifice Kit R0591601 R0591605 R0591602 R0591606 R0591603 R0591607 R0591604 R0591608 5 Gas Valve R0591...

Страница 42: ...R0589700 R0589700 R0589700 R0589700 3 Bypass Kit R0589800 R0589800 R0589800 R0589800 4 Drain Plug Kit R0446600 R0446600 R0446600 R0446600 5 Gasket and Seals Kit R0589500 R0589500 R0589500 R0589500 6...

Страница 43: ...arness Kit R0592100 R0592100 R0592100 R0592100 6 Air Pressure Switch Kit R0456400 R0456400 R0456400 R0456400 7 Vent Limit Switch Kit R0524300 R0524300 R0524300 R0524300 8 Water Pressure Switch Kit R00...

Страница 44: ...2 6 400 2 2 94 0 8 800 2 9 800 2 5 105 0 9 1000 3 0 1000 2 6 128 1 0 A saturation index of 0 is perfectly balanced A negative saturation index has corrosive tendencies A positive saturation index has...

Страница 45: ...Page 45 ENGLISH Jandy Pro Series JXi Gas Fired Pool Spa Heater Installation Operation Manual NOTES...

Страница 46: ...Page 46 ENGLISH Jandy Pro Series JXi Gas Fired Pool Spa Heater Installation Operation Manual NOTES...

Страница 47: ...Page 47 ENGLISH Jandy Pro Series JXi Gas Fired Pool Spa Heater Installation Operation Manual NOTES...

Страница 48: ...81 1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective ow...

Отзывы: