6.2  SPECIAL AUXILIARY LABELS

Air Blower 

When an AUX button labeled “Air Blower” is pressed, it will turn on the air 

blower for 30 minutes, then automatically turn it off. An air blower may be programmed 

like any other auxiliary, except that you can program only the ON time. The air blower 

will turn on at the programmed ON time, and turn off 30 minutes later. This is to protect 

the blower motor from overheating during extended operation. To change the ON 

time from the default value of 30 minutes, refer to the DEVICE RUNTIME feature.

Extra AUX 

System features (for example, light dimming, software labeling, and timed aux) 

can be assigned to the extra AUX button. Only freeze protection cannot be assigned 

to the extra auxiliary.

Fill Line 

When an AUX  button labeled “Fill Line” is pressed, it will turn on the fill line 

for 30 minutes, and then automatically turn it off. A fill line may be programmed like 

any other auxiliary, except that you can program only the ON time. The fill line will 

turn on at the programmed ON time, and turn off 30 minutes later. This is to avoid 

overfilling the pool. Choose the appropriate number of “fill” programs during the week 

to keep your pool at the appropriate level. To change the ON time from the default 

value of 30 minutes, refer to the DEVICE RUNTIME feature.

Spare AUX 

With DIP Switch S1-6 turned OFF, the spare auxiliary socket is energized in 

“Pool Mode” and off in “Spa Mode”. With DIP Switch ON, the spare Auxiliary socket 

is energized in the “Spa Mode” and off in the “Pool Mode”. Operates only with Pool/

Spa combination units.

6.3  CONTROLLER MESSAGES

CLEANER CANNOT BE TURNED ON WHILE SPA IS ON 

This message is 

displayed if the pool cleaner is activated when in spa mode (i.e., water is circulating 

to spa). The pool cleaner requires that water be circulating to the pool in order for it 

to operate. Return to pool mode to activate the cleaner.

CLEANER CANNOT BE TURNED ON WHILE SPILLOVER IS ON 

The return 

valve has been rotated to the spa position to give the spa spillover effect.

FREEZE PROTECT 

This message indicates that freezing conditions have been detected 

by the freeze protection sensor, and that equipment assigned to freeze protection (e.g., 

filter pump) are active. See the Section “3.5.4 Freeze Protect”, for more information. 

NOTE 

Only the filter pump is protected unless the optional freeze 

sensor is installed. If a freeze protected Auxiliary is turned off during 

freeze protection, a message will be displayed indicating that item 

is off but will turn on in X amount of minutes. The minutes will vary 

depending on how long freeze mode has been active from 1 to 15 

minutes. 

POOL HEATER ENABLED 

This message indicates that the pool heater is ready to use 

but is not actually firing. The filter pump must be on, and the water temperature must 

be below the setting for the heater to fire.

PUMP WILL REMAIN ON WHILE SPILLOVER IS ON 

This message is displayed 

when you attempt to turn off the filter pump while a spa spillover is on. Since the 

filter pump is necessary for spillover operation, the pump will remain on until the 

spillover is turned off.

Содержание AquaLink RS OneTouch Control Systems

Страница 1: ...ment exists the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Befor...

Страница 2: ...Page 2 ENGLISH AquaLink RS OneTouch Owner s Manual...

Страница 3: ...al Equipment 20 4 3 3 Variable Speed Pump 21 4 3 3 A Variable Speed Pump Setup 21 4 3 3 B Pump Model 21 4 3 3 C Pump Application 21 4 3 3 D Min Max Settings 22 4 3 3 E Speed Labels 22 4 3 3 E 1 Set Sp...

Страница 4: ...Custom Labeling 43 5 2 2 Auto Switching 43 5 3 OneTouch 44 5 3 1 OneTouch Setup 44 Section 6 Glossaries 45 6 1 Safety Delays And Lockouts 45 6 2 Special Auxiliary Labels 46 6 3 Controller Messages 46...

Страница 5: ...al temperature of the body The effects of hyperthermia include 1 unawareness of impending danger 2 failure to perceive heat 3 failure to recognize the need to exit spa 4 physical inability to exit spa...

Страница 6: ...y of drowning Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa Persons using m...

Страница 7: ...ith a no 8 AWG 8 4mm2 copper wire to any metal ladders water pipes or other metal within five 5 feet 1 52m of the pool spa In Canada the bonding wire must be minimum 6 AWG 13 3mm2 WARNING A ground fau...

Страница 8: ...AIR 79 06 02 03 MON 6 00 PM EQUIPMENT ON OFF MENU HELP ONETOUCH ON OFF Main System Menu System Menu 2 System Menu 3 Up and Down Scroll Keys Scroll within current menu can be held for continuous scrol...

Страница 9: ...aLink RS system is in service or time out mode will return the system to auto mode In previous firmware versions the system defaults to the last mode of operation SPA MODE ON CLEAN MODE OFF ALL OFF NE...

Страница 10: ...ter custom information for your local or preferred service center JANDYAquaLinkRS 01 31 03 Mon 6 00 PM Equipment ON OFF Onetouch ON OFF Menu Help 79 F Air Filter Pump OFF Menu Help Program Set Time Se...

Страница 11: ...es for daylight savings Daylight Saving Time in the United States begins at 2 00 a m on the second Sunday of March and ends at 2 00 a m on the first Sunday of November For details please visit www nis...

Страница 12: ...s water levelling and sprinkler system programs based on the seasons when outdoor temperatures and daylight hours typically change 12 00 AM System Setup In Floor Clean Solar Priority Pump Lockout Assi...

Страница 13: ...4 2 Set Temp 3 5 2 TEMP CALIBRATE SYSTEM SETUP MENU HELP Select to adjust the temperature displayed on the AquaLink RS system Temperature can only be adjusted by 4 F up or down and should be made for...

Страница 14: ...tect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protection...

Страница 15: ...RS operations When LOCK is displayed any changes to programs or system setup features are prevented When SpaLink and Spa Switch display LOCK all controls for both systems are deactivated Devices disp...

Страница 16: ...he systems programs or devices do not require Lockouts to be set Menu Help Program Set Temp Set Time Display Light Lockouts Program Group System Setup Password Enter Password 1 2 3 4 Use ARROW KEYS to...

Страница 17: ...at has been turned on manually or by a program This includes heater enables that were on unless in use by the Maintain function System Setup Solar Priority Assign Jvas Dimmers Color Wheels Spa Switch...

Страница 18: ...n pump on and off Circulates the pool or spa water through the filter and heater Will activate if the spa pool cleaner or spa spill over are activated Must be on to display the pool temperature or to...

Страница 19: ...IPMENT EQUIPMENT ON OFF Select to turn the main filtration pump on and off For dual equipment configurations additional equipment options will be available and both the filter pump and spa pump can op...

Страница 20: ...th a start time earlier than the current time will execute on the following programmed day 4 3 2 c SPA DUAL EQUIPMENT EQUIPMENT ON OFF Select to turn spa pump on For dual equipment configurations addi...

Страница 21: ...t to set pump application Up to 4 variable speed pumps can be controlled and assigned a specific application based on equipment installed see table below The default setting is NOT INSTALLED The pump...

Страница 22: ...r Pool Spa only Default Pool Spa Only Pool Spa Combo 1 POOL POOL 2 SPEED 2 SPA 3 SPEED 3 SPEED 3 4 SPEED 4 SPEED 4 5 TEMP 1 POOL HEAT 6 TEMP 2 SPA HEAT 7 SPEED 7 SPEED 7 8 INFLOOR INFLOOR CLEANER will...

Страница 23: ...endent auxiliaries AUX When the auxiliary is activated the pump will run at the assigned speed If more than one auxiliary AUX is turned on with an assigned speed the default will be for the pump to ru...

Страница 24: ...k RS 2 6 operates similarly to Pool Spa Only Low speed is enabled for the spa pump only To run pool pump at low speed an auxiliary must be assigned 4 3 4 d TWO SPEED PROGRAMMING ALL UNITS Programming...

Страница 25: ...HELP Select to ENABLE or DISABLE the automatic in floor cleaning feature When enabled the AquaLink RS system rotates the in floor Jandy Valve Actuators JVAs every 20 minutes Filter Pump OFF Pool Heat...

Страница 26: ...IN The system will periodically activate the pump sample water temperature and operate the heater to maintain the preset temperature Heater must be enabled for this feature to run effectively See Sect...

Страница 27: ...her the thermostat temperature is reached or solar heat is no longer available If solar panel is not hot enough solar heat will shut off and other heat source normally gas heater will take over to bri...

Страница 28: ...OLAR HEAT HEAT PUMP CHILLER and or EXTRA AUX simultaneously without RS485 control With RS485 Control SOLAR HEAT and HEAT PUMP CHILLER functions can be maintained and operated simultaneously Filter pum...

Страница 29: ...ater are enabled solar will heat the water until either the thermostat temperature is reached or solar heat is no longer available If solar panel is not hot enough solar heat will shut off and other h...

Страница 30: ...e the default when turning on a pool or spa light manually through the OneTouch control panel or a program Press the Back key to accept the last selected light color After 15 seconds without pressing...

Страница 31: ...ulse control After 15 seconds without pressing any keys the most recently selected LPC4 function will be accepted again IMPORTANT Do not activate this feature unless you are certain that a Laminar Pul...

Страница 32: ...N OFF Select to access the SPRINKLERS sub menu Set up start and run time programming via Sprinklers Setup menu in the System Setup menu See Section 4 6 5 Programming Sprinkler System for more details...

Страница 33: ...state 4 6 1 CANCEL TODAY SPRINKLERS EQUIPMENT ON OFF Select to set a 24 hour delay of the sprinkler system This feature may also be used to quickly turn off all sprinkler valves 4 6 2 MANUAL START SPR...

Страница 34: ...ON OFF menu Up to three 3 programs can be scheduled with different run days start times and durations Sprinklers Aux5 OFF OFF OFF OFF OFF OFF OFF Aux6 Aux5 Extra Aux Sprinklers Spa Mode Pool Heat Can...

Страница 35: ...are activated in numerical order for the set duration time There is a 1 2 second delay between valve activations START 8 00AM Sprinkler Setup Highlight an item and press SELECT Program 2 ON Start 9 3...

Страница 36: ...ssing CONTINUE with start times of each program for review Press EDIT to continue programming and press DONE to return to the SPRINKLER SETUP screen 4 7 CONTROLS 4 7 1 RS INTERLINK PWR CTR B EQUIPMENT...

Страница 37: ...1 and AUX 2 After completing one equipment assignment the previous menu will appear to continue the process A label pack is provided to label the buttons on the switch RS Interlink Setup Custom Label...

Страница 38: ...he previous menu will appear to continue the process A label pack is provided to label the buttons on the switch System Setup Solar Priority Assign JVAs Dimmers Spa Switch Spa Link Service Info Clear...

Страница 39: ...ered AQUAPURE ADJUST will set the AquaPure output for both pool and spa while the pool is covered Disable Devices Cover Closed Aux1 Aux2 Aux3 Aux4 Aux5 Aux6 Aux7 Cover pools Setup When Cover Is Closed...

Страница 40: ...luding iAquaLink but can only be set up from the OneTouch control panel Assign Jvas Intake Return Cleaner Solar Used Used Free Used System Setup Solar Priority Assign JVAs Dimmers Color Wheels Spa Swi...

Страница 41: ...he manual operation of the filter pump Boost is not available in Spa mode WARNING The AquaLink RS is compatible with only Jandy AquaPure Jandy PureLink amd Clormatic branded Electronic Chlorine Genera...

Страница 42: ...be set for all days weekends weekdays or specific days of the week Each piece of equipment can be programmed for multiple on off times each day Programs can be added deleted or changed as needed Prog...

Страница 43: ...AUTO SWITCHING PROGRAM GROUP MENU HELP Select to automate the switching of the operation of GROUP A or GROUP B on specific dates MENU Help Program Set Temp Set Time Display Light Lockouts Program Grou...

Страница 44: ...acters 1 IntelliFlo and IntelliPro are registered trademarks of Pentair Pool Products Inc 2 SAm SAL is a registered trademark of Pentair Pool Products Inc 3 Color Logic is a registered trademark of Ha...

Страница 45: ...er Short Cycling Prevention When the heater is activated and the desired temperature is reached heater will turn off and remain off for 3 minutes even if the temperature falls below the desired temper...

Страница 46: ...DIPSwitch ON the spareAuxiliary socket is energized in the Spa Mode and off in the Pool Mode Operates only with Pool Spa combination units 6 3 CONTROLLER MESSAGES CLEANER CANNOT BE TURNED ON WHILE SPA...

Страница 47: ...s not operational Service mode is used by the pool service person to aid them in servicing the pool The Controller will not be functional until the switch at the Power Center is moved back to AUTO mod...

Страница 48: ...HEAT SPA HEAT CHILL HOURS MODEL SENSORS REMOTES ADD PROGRAM DELETE CHANGE ERRORS EQUIPMENT EQUIPMENT MODE DIAGNOSTICS OFF POOL SPA MAINTAIN EQUIPMENT HELP PROGRAM SYSTEM SPA SWITCH SPA LINK DEVICES SY...

Страница 49: ...MP APPLICATION SELECT PUMP SCALE MIN MAX SELECT PUMP SPEED LABELS SET SPEED SELECT A DURATION VALUE SET DURATION SELECT PUMP PRIME DUSK SETUP PROGRAM 1 PROGRAM 2 PROGRAM 3 SPRINKLERS ENABLED DISABLED...

Страница 50: ...Page 50 ENGLISH AquaLink RS OneTouch Owner s Manual NOTES...

Страница 51: ...AquaLink RS OneTouch Owner s Manual Page 51 ENGLISH NOTES...

Страница 52: ...00 822 7933 www ZodiacPoolSystems com Zodiac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com DATE OF INSTALLATION _________________________________________ I...

Отзывы: