INSTALLATION 

2.1

 

Initial Inspection 

The  Jands  JLX-LITE-MkII  Lighting  bar  should  be  inspected  prior  to  installation.  Any  dents,  cracks  or 
damage that appears to have been suffered in transit should be photographed and the freight company 
notified before proceeding. 

 

2.2

 

Planning - Mechanical 

The  Jands  JLX-LITE-MkII  should  be  installed  by  persons  familiar  with  the  installation  of  load  bearing 
structures.  

 

 

 

 

WARNING

 

Failure to correctly install the JLX-LITE-MkII may  

result in injury or death

 

 

 

The JLX-LITE-MkII has been designed  to be mounted in various ways depending on the building struc-
ture it is being mounted to. Fixing methods include, but are not limited to: 

 

Direct to a concrete slab using chemical or expanding anchors.  

 

Direct into ceiling joists using timber screws, possibly  through an intermediate layer of plaster-
board. 

 

Suspended using droppers. 

 

Into  another  supporting  structure  using  nuts  and  bolts.  Note  mounting  to  suspended  ceiling  is 
not recommended as these are generally not strong enough to support the required load. If the 
JLX-LITE-MkII must be mounted against a suspended ceiling it should be mounted to the struc-
ture above the ceiling using droppers. 

 

Fixed using standard strut or other additional dedicated structure mounted either along the bar 
or preferably perpendicular to the bar. for example surface mounted standard strut. 

Do not mount the JLX-LITE-MkII using plasterboard fasteners of any kind - the JLX-LITE-MkII must be 
fixed to a solid structure. 

When locating the fixings, plan the layout so that: 

 

there  is  at  least  one  substantial  fixing  for  example  masonry  anchor,  per  bar  support  i.e.  for  a 
2.4m JLX-LITE-MkII use at least 4 substantial fixings; for a 1.6 m JLX-LITE-MkII use at least 3 
substantial fixings. When using less substantial fixings, for example wood screws, use at least 
twice the number of fixings and distribute them as evenly across the base as possible. 

 

the fixings are located as close as practical to the bar supports. 

 

if  mounting  the  JLX-LITE-MkII  to  strut,  ensure  that  the  strut  is  fixed  to  the  structure  on  either 
side of the JLX-LITE-MkII i.e. the strut is not cantilevered.  

 

when installed the mounting face of the duct will be within about 6 degrees of horizontal in both 
lengthwise and crosswise directions. If this cannot be achieved  in the lengthwise direction, use 

Содержание JLX-LITE-MkII

Страница 1: ...Modular Lighting Bar System JLX LITE MkII USER GUIDE ...

Страница 2: ... repairs on this product be carried out by JANDS Pty Ltd or its authorised service agents JANDS Theatre equipment must only be used for the purpose they were intended by the manufacturer and in conjunction with this user guide JANDS Pty Ltd will not accept any liability whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel or by use other than that int...

Страница 3: ... 2 3 Planning Electrical 4 2 4 Installation 4 2 5 Perch Bar Vertical Installation 6 2 6 Installation Record 8 3 INSPECTION MAINTENANCE 9 3 1 Annual Equipment Inspection Maintenance Log 10 4 TECHNICAL DATA AND SPECIFICATIONS 11 4 1 Rated Capacity 12 4 1 1 Definitions of Load 12 4 1 2 Maximum Point Load 12 4 1 3 Maximum Uniformly Distributed Load UDL 12 4 2 Mounting Hole Detail 13 ...

Страница 4: ...ncluding Surface mounted to ceiling On a surface mounted frame Suspended from threaded rods Vertical mounting as a Perch Bar The Jands JLX LITE MkII is suitable for fixed indoor applications only and is not protected against the ingress of moisture The JLX LITE MkII is not rated as a lifting bar under AS4991 The JLX LITE MkII is supplied unwired and the wiring should be installed by a licensed ele...

Страница 5: ...f the JLX LITE MkII must be mounted against a suspended ceiling it should be mounted to the struc ture above the ceiling using droppers Fixed using standard strut or other additional dedicated structure mounted either along the bar or preferably perpendicular to the bar for example surface mounted standard strut Do not mount the JLX LITE MkII using plasterboard fasteners of any kind the JLX LITE M...

Страница 6: ... a small number of outlets for example one circuit feeding two out lets Circuits may run direct to a switchboard or to a patch panel if dimming may be required This is suited to intermediate installations Individual circuits wired to a patch panel This is the most flexible arrangement allows circuits to be used as dimmers or direct power at will The mains outlets are available on one side of the b...

Страница 7: ...ide 8 Run and terminate the mains wiring The Jands JLX LITE MkII is supplied as a wiring enclosure for installation by a licensed electrician to AS NZS 3000 wire links are supplied to earth the socket outlets to a nearby tab on the chassis Bend the tabs inwards before fitting the earth link wire 9 If using the ELV compartment run and terminate the low voltage wiring then fit wire the con nectors 1...

Страница 8: ...nt the Perch Bar option at the low end of the bar When correctly installed the Perch Bar option allows the JLX LITE MkII bar to be used at the rated working load limit Note at high bar angles the bar will transfer the bulk of the load to the supporting structure via the Perch Bar mount at the bottom Hence this mount must be well fixed to the supporting structure using multiple solid anchors that i...

Страница 9: ...iring then fit wire the con nectors 11 Check the Earth continuity of all external parts and the socket outlet Earths 12 Test the wiring as required by AS NZS 3000 13 Load test the bar 14 Check the fixings are all in tact and none have significantly deformed as a result of the load test At the same time double check all fasteners are secure and are using load spreading washers Also check there is a...

Страница 10: ... person installing the lighting bar s Where more than one person has installed the lighting bar s the foreman supervisor or similar person responsible for the works should fill out and sign this record Product JANDS JLX LITE MkII Number of Bars Serial Number s Project Name Job No Installed By Company Comments Name Signature Date ...

Страница 11: ...be carried out annually on both the mechanical structure and the electrical wiring etc by appropriately qualified persons Fill out the serial numbers for the inspection maintenance logs then copy the pages for future use All the records should be kept for future reference WARNING The JLX LITE MkII should be regularly inspected by an ap propriately qualified person s ...

Страница 12: ... outlets for evidence of wear and damage Inspect mains cable and plugs for evidence of wear and damage Inspect all screws nuts bolts for correct tightness and physical integrity Inspect the visible portions of the central extrusion for distortion or cracks Inspect attachment clamps brackets and standoffs for distortion or damage Perform safety tests test tag to AS3760 Comments Name Signature Test ...

Страница 13: ...istributed Load in cluding any point loads in a given span 50kg m Working Load Limit 100kg 150kg Total Torsional Load on bar 10Nm 15Nm Bar Length 1600mm 2400mm Depth 147mm Height 207mm Net Weight 9kg 12kg Ingress Protection IP2X Specification only valid when the top face of the duct is horizontal in both the crosswise and longitudinal directions This specifi cation is reduced when the JLX LITE MKI...

Страница 14: ...that the bar is permitted to carry It is made up of a combination of point loads and distributed loads 4 1 2 Maximum Point Load This is the maximum individual load that can be applied to a JLX LITE MkII An example would be a single light attached to the Bar Figure 4 1 Point Load In addition the sum of all point loads between two bar hangers must not exceed the specified maxi mum 4 1 3 Maximum Unif...

Страница 15: ...USG 00000 JLXLITEMKII 1 0 JLX LITE MKII 13 4 2 Mounting Hole Detail ...

Отзывы: