background image

GT2

 Calibration Guide

 

Janam Technologies LLC

2

Step 3

Compare the average values from Steps 1 and 2. If these two values are different, the temperature 
reading must be calibrated. To prepare for calibration, complete the following steps:

1.

 Connect to Wi-Fi, record the IP address on the screen

2.

 Input the IP address plus +port 8090 in the PC Chrome window (Example: 192.168.8.2

8090)

3.

 Access the control panel by entering the password “123456”

4. Access 

S

ettings 

by clicking the gear icon on the blue menu bar at the bottom of the menu

Step 4

In the temperature measurement calibration field, enter the difference between the FDA-approved 
thermometer (Step 1) and GT2’s temperature reading functionality (Step 2). For the example used, 
the value that should be entered is “0.1”. 

Positive calibration (“compensation”) is between 0.0 ~ 10.0

Negative calibration (“compensation”) is between -0.0 ~ -10.0

Отзывы: