background image

Rod

Stuffing 

Box Cap

O-ring

1/4” 

Grease 

Fitting

Stuffing 

Box Body

End 

Ferrule

Spring 

Leader 

Accessory

Screws

Live Tracer Operation

Before Each Use:

Inspect O-ring

 for any sign of tearing, cracking or pitting. Replace if damaged BEFORE EVERY USE. Jameson O-rings 

are custom designed.  Only Jameson-provided O-rings will guarantee proper safety and effectiveness.

Inspect rod 

for damage. If rod surface is broken, replace rod.  A scratched rod could cause leaking when scratch passes 

through Stuffing Box O-ring.  Portions of rod can be cut away and new end fitting attached if it is not necessary to replace 

entire rod.

Follow your company safety procedures at all times. These instructions shall not take the precedence over any safety 

procedures established by your company.

1. Access PE gas pipe to be traced.  Install electrofusion Tap Tee to pipe.  Follow all installation and safety procedures 

   provided with your equipment and those established by your company.

Install Rod into Stuffing Box

2.  Remove cap of Stuffing Box by removing the 3 screws.

3.  INSPECT O-RING.  If it shows any sign of tearing, cracking or pitting, replace with 

     new O-ring. 

4.  Pay out rod approximately 15 feet.

5.  Remove spring accessory then install rod end through Stuffing Box cap as shown.

6.  Lubricate end ferrule, rod and inside O-ring with lubricated wipes provided.  Install 

     O-ring over rod.

7.  Insert rod end into Stuffing Box body.

8.  Attach Spring Leader Accessory to end ferrule of rod.

9.  Install Stuffing Box cap with 3 screws provided.  Snugly secure all screws to        

     ensure proper O-ring seal. 

10. Attach Stuffing Box to angled access port of Tap Tee. Follow your company’s 

      procedures for attaching to access port. 

11. Open valve and check for gas leaks following your company procedures.  If Stuffing

      Box is leaking, inspect O-rings and rod for damage.  Replace as necessary.

12. Mark rod with permanent marking pen 6” from Stuffing Box to monitor retracting 

      of rod.

800.346.1956

WWW.JAMESONLLC.COM

Содержание 16-14-600-GL

Страница 1: ...e regarding the use of its gas line tracer products Jameson LLC cannot be responsible for any use of its products that does not comply with these instructions However you are also cautioned to comply...

Страница 2: ...equip ment Failure to follow instructions could result in an accident causing serious injury Do not allow chil dren or untrained personnel to use this equipment Follow your company installation proced...

Страница 3: ...ed operating personnel only This publication was written to assist in the training of personnel in the appropriate procedures and operating tech niques for joining polyethylene pipe with the Jameson I...

Страница 4: ...apter Advance cutter with tapping tool until the stop is engaged completing hot tap Back out cutter with tapping tool and seal against top of tapping tee body This ensures cutter does not restrict flo...

Страница 5: ...procedures provided with your equipment and those established by your company Install Rod into Stuffing Box 2 Remove cap of Stuffing Box by removing the 3 screws 3 INSPECT O RING If it shows any sign...

Страница 6: ...below 45kHz Follow proper locating practices established by your company or your locating equipment manufacturer Removing the Rod 18 When tracing is complete pull rod back through Tap Tee and reinsta...

Страница 7: ...led rod Any resistance reading generally between 2 12 ohms indicates proper continuity 6 Remove end ferrule Clean rod end and end ferrule with cleaning solvent or alcohol to remove debris and glass fi...

Страница 8: ...oupling 45 10 20 1 0 10 1 IPS Coupling 50 10 20 1 0 10 2 Insertion Tee 90 10 25 1 0 10 Clamping required on couplings Warranty Jameson products carry a warranty against any defect in material and work...