![James Walker KlickFix Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/james-walker/klickfix/klickfix_installation-manual_3281590006.webp)
Seal Lip Deployment Guide for
Insert a small pry bar into each of the two
radial slots in the Deployment Sleeve, near
the gland plate.
Re-start the pump and check operation of
pump and seal.
Push the pry bars
simultaneously to move
the Deployment Sleeve
reaches the next
Positioning Clip (E-Clip).
The new sealing lip
is now
deployed.
Move Deployment Sleeve to next
Clip.
Schieben sie Einsatz Hülse zur
nächsten Klammer.
Spostare il pattino fino alla messa
in funzione della clip successiva.
Beweeg de verstelbare stationaire
asbus naar de volgende clip.
Deslizar el cartucho hasta la brida
del alojamiento. Fijar los tornillos
del alojamiento.
Reculer le manchon de maintien
des lèvres jusqu'au clip suivant.
Restart pump & check for leaks.
Far ripartire la pompa & controllare
le perdite.
Herstart de pomp en controleer
deze op lekkage.
Arrancar la bomba y chequear si
hay fugas.
Redémarrer la pompe et vérifier les
fuites.
Anschalten Sie die Pumpe wieder
und Prüfen für die Leckage.
Repeat sequences 13 - 17 for deployment of each new sealing lip when
leakage becomes visible.
Repeat 13-17 when leak appears.
Wiederholen Sie 13-17 wenn
Leckage erscheint.
In caso di perdita ripetere da 13 a
17.
Herhaal vanaf 13 tot en met17
indien lekkage optreedt.
Repetir 13 al 17 cuando aparezcan
fugas.
Répéter de 13 à 17 en cas de fuites.
James Walker KlickFix
®
Safety Data Sheets are available on request
Health warning
e should be taken to avoid contaminating tobacco with particles of
Information in this publication and otherwise supplied to users is based on our general experience and is given in good faith,
the use of products, no warranty is given or is to be implied with respect to such information. Unless governed by type approva
of operating limits quoted in this publication are not an indication that these values can be applied simultaneously.
ebsite: www.jameswalker.biz.
EN
DE
IT
NL
ES
EN
EN
DE
DE
IT
IT
NL
NL
ES
ES
F
F
F
James Walker & Co Ltd, Gote Brow, Cockermouth, Cumbria, CA13 0NH, United Kingdom
Tel:+44 (0)1900 823555 Fax:+44 (0)1900 898354 Email: [email protected]
Issue 1
JW4665/
0918