background image

 

 
 
 
 

Attention

 

 

Notes

 

for

 

Operation

 

1.

 

Before

  

using

  

this

  

product,

  

please

  

read

  

this

  

“Attention”

  

carefully,

  

and

 

                      keep

 

this

 

user

 

manual.

 

2.

 

Please

 

follow

 

the

 

mark

 

and

 

requirements

 

when

 

operate

 

the

 

machine.

 

3.

 

This

 

machine

 

should

 

be

 

far

 

away

 

from

 

sunshine,

 

rain

 

or

 

humidity.

 

4.

 

Keep

 

this

 

machine

 

away

 

from

  

electronic

 

equipments,

 

such

 

as

 

electric

 

warming

 

oven,

 

heating

 

furnace.

 

5.

 

Around

 

UPS

 

should

 

keep

 

some

 

space

 

for

 

ventilation.

 

Please

 

read

 

the

 

user

 

manual

 

when

 

you

 

install

 

this

 

UPS.

 

6.

 

Please

 

use

 

dry

 

articles

 

for

 

cleaning

 

UPS.

 

7.

 

Please

 

use

 

powder

 

fire

 

extinguisher

 

instead

 

of

 

liquid

 

fire

 

extinguisher

 

in

 

case

 

of

 

fire.

 

 

Notes

 

for

 

Electricity

 

1.

  

Please

  

confirm

  

whether

  

the

  

UPS

  

already

  

connect

  

to

  

the

  

ground,

 

check

 

the

 

cable

 

and

 

battery

 

before

 

start

 

the

 

UPS.

 

2.

  

When

  

move

  

UPS

  

or

  

connect

  

the

  

cable

  

again,

  

cut

  

off

  

the

  

AC

  

input

 

power,

 

make

 

sure

 

UPS

 

stop

 

working

 

completely,

 

otherwise

 

there

 

will

 

be

 

danger

 

on

 

the

 

output.

 

3.

   

Please

   

use

   

the

   

additional

   

equipments

   

and

   

accessories

   

of

   

our

 

company.

 

4.

  

Output

  

cable

  

of

  

UPS

  

should

  

be

  

no

  

longer

  

than

  

10m

  

in

  

order

  

to

  

meet

 

the

 

requirements

 

of

 

EMC.

 

 

Notes

 

for

 

Battery

 

1.

  

Life

  

of

  

battery

  

will

  

be

  

shorter

  

if

  

the

  

temperature

  

get

  

higher,

  

please

 

change

  

the

  

battery

  

regularly

  

and

  

make

  

sure

  

it

  

can

  

supply

  

enough

 

back-up

 

time.

 

2.

   

Maintenance

   

for

   

battery

   

should

   

be

   

operated

   

by

   

the

   

professional

Содержание JP5530 10K/RM10K

Страница 1: ...USER S MANUAL JP5530 6 20KVA...

Страница 2: ...her instead of liquid fire extinguisher in case of fire Notes for Electricity 1 Please confirm whether the UPS already connect to the ground check the cable and battery before start the UPS 2 When mov...

Страница 3: ...it is very dangerous 6 Short circuit of the two poles on a battery should not happen otherwise there will be fire or electric shock Maintenance 1 Life of UPS will be subject to the environment don t u...

Страница 4: ...Connection to the computer 11 2 6 Parallel optional 12 2 7 Installation for SNMP optional 15 2 8 EPO 16 2 9 Maintenance switch optional 17 2 10 Dust screen optional 18 2 11 Isolated transformer option...

Страница 5: ...oad disappear UPS will transfer to the inverter automatically This user manual can be applied for the following models JP5530 6K RM6K standard backup type with internal batteries JP5530 6KL RM6KL long...

Страница 6: ...d Meaning Attention Danger AC power DC power Protective Earth Conductor Protective Bonding Conductor Cycling Not Placed With Other Things Overload Battery On Off Button JP5530 6K 10K 15K 20K JP5530 6K...

Страница 7: ...3 JP5530 RM6K 10K JP5530 RM15K 20K 1 3 Rear Panel JP5530 6K JP5530 10K...

Страница 8: ...4 JP5530 6KL JP5530 10KL JP5530 15 20K...

Страница 9: ...maintenance switch maintenance switch is optional terminal board bracket for cable EPO optional Please Note 1 If UPS is with parallel card and maintenance switch please remove board and you will see...

Страница 10: ...th rated full load and charger works fully UPS can have the maximum current Load of the high altitude rated power Rating factor correspond to altitude Altitude m 1000 1500 2000 2500 3000 3500 4000 450...

Страница 11: ...o the ground 2 Installation 2 1 Check when open the package 1 Open the package and check whether there is any damage during the transportation 2 If there is any damage or lack of some instruments plea...

Страница 12: ...on Model JP5530 6K RM6K JP5530 6KL RM6KL JP5530 10K RM10K JP5530 10KL RM10K L JP5530 15K RM15K JP5530 20K RM20K Input G 10AWG 6mm 2 10AWG 6mm 2 8AWG 10mm 2 8AWG 10mm 2 6AWG 25mm 2 6AWG 25mm 2 N 10AWG...

Страница 13: ...input output cable connect the terminal fasten Terminal for UPS JP5530 6KL JP5530 6K JP5530 10KL JP5530 10K 7 Fix the cover plate with screws again 8 Connect wires and get mains then turn on the Inpu...

Страница 14: ...battery cabinet and UPS refer to table 2 2 An air DC switch must be connected between UPS and Battery groups the voltage and current of this switch cannot be less than parameters on batteries of each...

Страница 15: ...er socket Socket o f computer RS232 or USB will connect the UPS to the monitor 1 Connect the RS232 or USB to the socket of computer 2 Connect the RS232 or USB to the socket of UPS The feet bitmap of c...

Страница 16: ...lel cards and cables in this range 2 Installation for parallel This function is optional the user can buy parallel card and cable for installation and maximum three UPS for parallel each UPS must use...

Страница 17: ...rence of each wire which connects block and loads must be less than 10 if the distance between loads and every paralleled UPS is more than 20 meters 3 The input and output terminals of each paralleled...

Страница 18: ...nd transfer to inverter Start UPS when battery supply power press button of each UPS for a short time then press any one of the UPS for a longer time the other UPS will start and work at the battery m...

Страница 19: ...optional Install AS400 card to the socket the position as below meaning PIN1 Break over UPS fault PIN2 Break over alarm PIN3 Ground PIN4 Shut off UPS remote control PIN5 Public terminal non break over...

Страница 20: ...16 2 8 EPO EPO Emergent Power Off is on the real panel of UPS is green terminal 1 2 Close UPS shut off immediately 3 4 Doesn t work...

Страница 21: ...3 4 Open UPS shut off immediately 2 9 Maintenance Switch To realise online service of UPS following picture no matter mains battery or bypass mode internal sections of UPS have power maintenance switc...

Страница 22: ...this wan UPS can be saved without dust Installation of the dust screen as below 1 Remove front panel 2 Install dust screen 3 Install front panel 2 11 Isolated transformer box optional Isolated transf...

Страница 23: ...the mains mode means load at the battery mode means battery capacity 7 bypass orange 8 mains green 9 inverter green 10 battery orange 11 load capacity From right to left 6 2 the more LED flash less l...

Страница 24: ...speaker mute press more than 2 seconds at bypass or battery mode battery check press more than 2 seconds at mains mode 14 start shut off UPS LCD panel 1 5 LED 1 mains green 2 bypass orange 3 battery o...

Страница 25: ...to left battery capacity increase 6 start UPS Start UPS or increase when set the parameter 7 function button Adjust the parameter adjust BUS voltage inverter output voltage and change screen to the n...

Страница 26: ...use UPS at the first time LED status flash not flash Start UPS when the mains supply Press button more than 1 second UPS will start and check itself at this time LED for load battery capacity will fl...

Страница 27: ...t After starting UPS led for battery will flash led for mains will shut off load of the UPS will be supplied by the battery battery mode At the battery mode buzzer will alarm every 4 seconds if need l...

Страница 28: ...er alarm every 2 mints press loudspeaker mute more than 2 seconds if not need output disconnect mains 4 3 Start UPS on LCD Panel Start UPS with mains Press the button for more than 1 second UPS will s...

Страница 29: ...th DC Press the button more than 1 second UPS will start After starting battery light flashes mains light will be off load will be supplied power by the battery Battery Inverter Mode At the battery mo...

Страница 30: ...ut 5 Maintenance of the battery UPS will charge the battery all the time If UPS is not used for a long time charge the battery every 4 6 months If the temperature around is high charge or discharge th...

Страница 31: ...or the frequency of the mains is out of the range of UPS UPS is at the mode of battery save the data shut off the software make sure input voltage and frequency is within the range 1 2 flash the buzz...

Страница 32: ...95 load No 5 96 105 load No 6 Batter y mode 0 20 battery Alarm every 1 second 7 21 40 battery Alarm every 4 seconds 8 41 60 battery Alarm every 4 second 9 61 80 battery Alarm every 4 second 10 81 100...

Страница 33: ...m continuously 18 High temperature Alarm continuously 19 Inverter abnormal Alarm continuously 20 Output short circuit Alarm continuously 21 BUS voltage abnormal Alarm continuously 22 Charger or batter...

Страница 34: ...ery E7 Charger fault E8 Eeprom fault E9 EPO switch wrong F1 CAN cable fault F2 Short circuit of inverter voltage F3 Overload F4 High temperature F5 BUS voltage too high or too low F6 Too high or too l...

Страница 35: ...r board and replace it 6 F 01 Reason CAN cable fault Check Check the control board 7 F 02 Reason Short circuit of inverter voltage Check Check whether output short circuit 8 F 03 Reason output Overloa...