Using A, B and C buttons you should put the rod in a position, which will
make the rod able to reach square-shaped hole placed below and in the
center of a front.
A
–
the rod moves to right/left side
B
–
the rod moves to up/down side
C
–
the rod moves to front/back side
When the rod is placed in the hole already, confirm settings by pressing GO
button.
2) The device starts to autocalibrate
–
the rod reaches holes placed vertically
first, and later these placed horizontally.
3) If the rod does not reach any of holes, it is necessary to carry out all process
of the calibration again.
4) After calibration, the following message appears on the display, placed on the
control panel:
CALIBRATION OK
If the system was reseted (
SET DEFAULT
), it is necessary to calibrate the
device again.
CALIBRATION TEST
–
checking the calibration correctness of the device.
1) Press simultaneously DOWN and UP buttons. The following message appears
on the display, placed on the control panel:
CALIBRATION TEST
KEY GO