Version: 3.1.0
39
e.
After the sensor is installed and powered on, it is recommended to warm up for one hour before
operating.
f.
When using the sensor, pay attention to the mass of the device mounted on it, which should be within
the payload range of the robot.
g.
If you have any doubts or if any faults occur during use, please do not attempt to operate the product.
Instead, contact us directly.
2.1.5.7 Reference Tightening Torques for Sensor Mounting Bolts
Reference tightening torques for type VI sensor mounting bolts are as follows:
Table 2-13 Reference Tightening Torques for Type VI Sensor Mounting Bolts
Metric
Reference Tightening
Torque (Nm)
M2
0.4
M3
2.0
M4
4.0
M5
8.0
M6
13.0
M8
35.0