Page 75
VIS CAM 300/400 Installation Manual
Appendix B: J-Panel Functional and Connector Description
6.3.6 Indicators
There are two LED indicators mounted at the connector:
TABLE 22.
LED indicators
6.3.7 Switches
There are two switches located at the connector:
TABLE 23.
Connector switches
LED label
LED color
Indication
TRIG-1
green
Indicates generation of trigger pulse to camera
off
No trigger pulse
LC DATA
LED not mounted
Power
green
24V present at connector pin 10
red
No 24V at connector pin 10
Switch label
Switch type
Function
S1 TRIG CAM-1
Push button
Generates a trigger pulse to the camera
S5 TRIG POLARITY
Slide
Selects trigger polarity
Содержание Vehicle Imaging Subsystem 300