Configuring the TM-6740GE Camera
TM-6740GE Software
3
Configuring the TM-6740GE Camera
The configuration of your GigE camera consists of two parts:
•
The imager configuration (CCD and control circuits)
•
The internal frame grabber configuration
The imager can be configured for partial scan, binning, and so on, just like a Camera Link camera. The
internal frame grabber is automatically configured for the pixel type, windowing, image size, I/O and so
on, by the GigE camera software.
The TM-6740GE camera can operate in either 8-bit or 10-bit digital output mode. The 8-bit/10-bit
selection is possible through the GigE integrated software. To select the mode, open the Configure page
and select the Image Setting tab. Under the Pixel Type, select either Grayscale 8, 2 taps, or Grayscale
10, 2 taps. Note that when Grayscale 10, 2 taps is selected, the LUT (Look-Up Table) is not available in
this mode.
FIGURE 9.
Configuration Window
3.1 Setup
If you have a peer-to-peer connection between the TM-6740GE camera and your PC without network
switches, your packet size can be the default value (8128 bytes) as shown in Figure 7. However, if you
are connecting the TM-6740GE to your PC through a network switch, then you need to know the
maximum packet size the network switch supports. Typically, if your switch supports jumbo packets,
then you should keep the packet size to 8128 bytes. If your switch does not support jumbo packets, then
you may need to change the packet size to 1440 bytes.