SW-4000T-SFP
— 29 —
Gain Control
The following gain functions are available on the camera.
• Analog base gain
• Digital gain
■
Analog base gain
Analog base gain (ABG) is gain that is performed to the analog video signal output from the
sensor. The gain steps can be configured to one of three levels (0 dB, 6 dB, 12 dB).
■
Two digital gain control modes
Two digital gain control modes are available; a mode where you adjust the master gain and
then perform fine adjustment for R and B (Master Mode), and a mode where R, G, and B gain
are adjusted individually (Individual Mode).
・
Master Mode
Set [Individual Gain Mode] to [Off], and adjust the gain by configuring the following three
items.
Digital All
x 1
~
x 32
(0dB
~
30dB)
Digital Red
x 0.4
~
x 4 (
-
7.96dB
~
12dB)
Digital Blue
x 0.4
~
x 4 (
-
7.96dB
~
12dB)
・
Individual Mode
Set [Individual Gain Mode] to [On], and adjust the gain by configuring the following three
items.
Digital Green
x 1
~
x 64
(0dB
~
36dB)
Digital Red
x 1
~
x 64
(0dB
~
36dB)
Digital Blue
x 1
~
x 64
(0dB
~
36dB)
The following two gain values are added together for the total gain value.
Total Gain = Analog Base Gain (dB) + Digital Gain (dB)
*) In the IndividualGainMode, only AWB Once and AGC Once can be executed.