SW-2000M-CL-65
40
C – Commands affecting image output format
Command Function Command Format
Parameter
Remarks
1 Camera Link mode
CL MODE
<mode>
SINGLE 8
SINGLE 10
SINGLE 12
DUAL 8
DUAL 10
DUAL 12
TRIPLE 8
8 bits, 1 pixel/clock
10 bits, 1 pixel/clock
12 bits, 1 pixel/clock
8 bits, 2 pixels/clock
10 bits, 2 pixels/clock
12 bits, 2 pixels/clock
8 bits, 3 pixels/clock
2
Camera Link clock
frequency
CL RATE
<rate>
CL RATE MIN
From 20 to 85 MHz.
MIN is to use the slowest
sufficient rate.
Both in steps of 5 MHz.
3 Readout direction
READOUT
Normal or Reverse
4
Set the regions of
interest
ROI
<regions>
Pixel numbers, 1 to 4
regions.
5 Activate ROI
ROI ON
6 Deactivate ROI
ROI OFF
7 Pixel binning
BINNING
<mode>
AVG, SUM or OFF
D – Utilities
Command Function Command Format
Parameter
Remarks
1 Help
HELP
or ‘?’
list of commands
2
Help on any specific
command
add a ‘ ?’
examples:
GAIN ?
LINE RATE ?
3
Query of existing
setting
<command> with no
parameters
examples:
GAIN
LINE RATE
4
Camera information
and settings
STATUS
4
Camera identifiers
and version numbers
VER
Model, SN, MAC.
Versions: MCU, HW,
sensor, logic.
5
Selection of test
patterns
TEST
<pattern>
TEST OFF
From P1 to P5
6
Re-booting the
camera
REBOOT
close telnet sessions
7
Firmware update
FIRMWARE
UPDATE
http://10.10.10.10