SW-2000M-CL-65
39
B – Commands affecting exposure
Command Function Command Format Parameter
Remarks
1
Sensor operating
mode
SENSOR
DYNAMIC
RESPONSIVE
Larger capacity,
lower noise.
Smaller capacity,
higher responsivity.
2 Line interval
LINE PERIOD <time>
Line interval in µs, from
15.3 to 100 000
Minimum depends
on CL mode and
rate, ROI and
binning
3 Line rate
LINE
RATE <rate>
Lines per second, from 10
to 65,000
Maximum depends
on CL mode and
rate, ROI and
binning
4
Timing source
LINE CTRL <mode>
INT = internal
EXT = external
MIX = external line timing,
internal integration time
5
Integration
time as
microseconds
LINE IT <time>
2.00 to 99,998.60 µs
Minimum and
maximum depend
on line rate
6
Integration time as
percentage
LINE IT <time>%
0.10 % to 100.00 %
7 Gain
GAIN
<gain>
0.100 to 32.000
digital
8 Offset
OFFSET
<offset>
-1023 to 1023
entered as 12 bits
9
Calibrate the Flat
Field Correction
FFC
RUN
define and apply
10 activate correction FFC ON
11 deactivate
FFC OFF