— 37 —
SP-12000M-CXP4 / SP-12000C-CXP4
Bayer color
X89.12
X16
X7.15
X5.62
X1
X0.45
1600
0
37876 (X5.62)
0 (X1)
–4533 (X0.45)
R&B
Red
Blue
39dB
-7dB
0dB
24dB
15dB
0dB
–7dB
15dB
0dB
–7dB
15dB
37876 (X5.62)
0 (X1)
–4533 (X0.45)
Gain
setting
value
Master
Master
Gain
amplification
Gain setting
value (scaling)
Gain adjustment range (Bayer color)
LUT (Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 256 setting
points (indexes).
■
To use the LUT function
Configure the settings as follows.
Item
Setting value / selectable range
Description
JAI LUT Mode LUT
Use LUT.
LUT Selector*
R, G, B
Select the LUT channel to control.
LUT Index
SP-12000M-CXP4: 0 to 255
SP-12000C-CXP4: 0 to 255
Select the LUT index to configure.
Indexes represent the possible pixel values captured on the
sensor, from the lowest value (Index 0) to the highest (Index
255). For example, Index 0 represents a full black pixel and
Index 255 represents a full white pixel.
LUT Value
0 to 4095
Set the LUT output value for the selected index.
* SP-12000C-CXP4 only
Note
R, G, and B are configured separately on the SP-12000C-CXP4.
■
LUT values
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate