User Manual (Ver. 1.0) - Setting List
GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
- 119 -
DeviceControl Item
Setting
Range
Default Value
Description
DeviceManifest
PrimaryURL
-
-
Display the PrimaryURL.
DeviceManifest
SecondaryURL
-
-
Display the SecondaryURL.
DeviceTLType
0:GigEVision
(Fixed)
-
Transport Layer type of the device.
DeviceTLVersionMajor
2 (Fixed)
-
Indicates the major version number of the device's Transport Layer.
DeviceTLVersionMinor
0 (Fixed)
-
Indicates the minor version number of the device's Transport Layer.
DeviceTLVersionSubMinor
1 (Fixed)
-
Indicates the sub-minor version number of the device's Transport
Layer.
DeviceLinkSelector
0 (Fixed)
0
Select Link.
DeviceLinkSpeed
-
125000000
Bps
Displays the negotiated transmission rate.
DeviceLinkHeartbeatMode
0:Off
1:On
1:On
Enable/Disable Heartbeat mode.
DeviceLinkHeartbeatTimeout
500000 ~
120000000
3000000
Configure the timeout value for Heartbeat (unit: μs). Step: 1000
DeviceStreamChannelCount
1 (Fixed)
-
Display the number of supported stream channels.
DeviceEventChannelCount
1 (Fixed)
-
Display the number of supported message channels.
DeviceCharacterSet
1: UTF8
(Fixed)
-
Display the character encoding.
DeviceReset
-
-
Reset the device.(After the camera receives this command, it
returns an ACK response and executes the reset.)
DeviceRegistersEndianness
1:big-endian
(Fixed)
-
Display the register's endianness.
DeviceTemperatureSelector
0: Mainboard
1: Sensor
2: FPGA
3: PHY
0: Mainboard
Select the area of the camera's interior for which to display the
temperature sensor's reading.
Related Topic:
Notes on Supplying Power via PoE
DeviceTemperature
-55 ~ 125
0
Display the internal temperature (°C) of the device specified by
DeviceTemperatureSelector.
Timestamp
0 ~ 64bit max
0
Display the timestamp value (ns). Resets to 0 when the signed
maximum 64-bit value is exceeded.
TimestampReset
-
-
Forcibly sets the timestamp's count value to 0.
TimestampLatch
-
-
Sets the timestamp's count value to TimestampLatchValue.