0 (Fixed)
0
Selects the stream channel to control.
GevSCCFGPacketResendDestina
tion
True, False
False
Sends a test packet. When this feature is set, the device will fire one test
packet.
GevSCCFGAllInTransmission
True, False
False
GevSCCFGUnconditionalStreami
ng
True, False
False
GevSCCFGExtendedChunkData True, False
False
GevSCPInterfaceIndex
0 (Fixed)
0
GevSCPHostPort
0 (Fixed)
0
Controls the port to which the device must send messages.
GevSCPSFireTestPacket
True, False
False
GevSCPSDoNotFragment
True, False
False
The state of this feature is copied into the "do not fragment" bit of IP header
of each stream packet.
It can be used by the application to prevent IP fragmentation of packets on the stream channel.
GevSCPSPacketSize (B)
1476〜12036 step 4
1476
This GigE Vision specific feature corresponds to
DeviceStreamChannelPacketSize and should be kept in sync with it.
It specifies the stream packet size, in bytes, to send on the selected channel for a GVSP
transmitter or specifies the maximum packet size supported by a GVSP receiver.
GevSCPD
0〜4000000 step 8
0
Controls the delay (in GEV timestamp counter unit) to insert between each
packet for this stream channel.
This can be used as a crude flow-control mechanism if the application or the network
infrastructure cannot keep up with the packets coming from the device.
GevSCDA
ー
ー
Controls the destination IP address of the selected stream channel to which a
GVSP transmitter must send data stream or the destination IP address from
which a GVSP receiver may receive data stream.
GevSCSP
ー
ー
Indicates the source port of the stream channel.
Configure settings for action control.
0x00000000 〜 0xFFFFFFFF
ー
An action command is executed if this ActionDeviceKey matches the
DeviceKey contained in the action command message.
1,2
1
select the ActionSelector.
ActionGroupMask
0x00000000 〜 0xFFFFFFFF
ー
An action command is executed if the result of an AND operation of
GroupMask contained in this ActionGroupMask and an action command
message is not 0.
ActionGroupKey
0x00000000 〜 0xFFFFFFFF
ー
An action command is executed if this ActionGroupKey matches the GroupKey
contained in the action command message.
Configure user settings.
Default, UserSet1,
UserSet2, UserSet3
Default
Select the user settings.
UserSetLoad
0(default), 1, 2, 3
ー
Load user settings.
(If 0 is specified, the factory default setting is read.)
UserSetSave
1,2,3
ー
Save the current setting values as user settings.
Configure chunk control settings.
True, False
False
Set whether to enable ChunkData.
ー
ー
The value of OffsetX (ChunkID 2000h : DataType Integer)
ー
ー
The value of OffsetY (ChunkID 2001h : DataType Integer)
ー
ー
The value of Width (ChunkID 2002h : DataType Integer)
ー
ー
The value of Height (ChunkID 2003h : DataType Integer)
ー
ー
The value of LineStatusAll (ChunkID 2013h : DataType Integer)
The value of ExposureTime (ChunkID 2004h : DataType Integer)
ー
ー
The value of AnalogGainAll (ChunkID 201Fh : DataType Float)
ー
ー
The value of DigitalGainRed (ChunkID 2006h : DataType Float)
ー
ー
The value of AnalogGainBlue (ChunkID 2007h : DataType Float)
ー
ー
The value of FrameTriggerのCounter (ChunkID 200Eh : DataType Integer)
ー
ー
The value of SequencerSetActive (ChunkID 200Ch : DataType Integer)
k) ActionControl
l) UserSetControl
m) ChunkDataControl
ChunkGainAnalogAll
ChunkLineStatusAll
GevStreamChannelSelector
ChunkGainAnalogBlue
ChunkSequencerSetActive
ChunkExposureTime
ChunkGainDigitalRed
ChunkFrameTriggerCounter
ActionDeviceKey
ActionSelector
ChunkModeActive
ChunkOffsetX
ChunkOffsetY
ChunkWidth
ChunkHeight
UserSetSelector
ActionQueueSize
—
71
—
Go-X Series GigE Vision I/F
Содержание Go-X Series
Страница 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79 ...
Страница 80: ... 80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F ...
Страница 81: ... 81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F ...
Страница 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82 ...
Страница 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83 ...
Страница 84: ... 84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F ...
Страница 88: ... 88 Revision Date Changes Revision history Go X Series GigE Vision I F ...