— 14 —
Note
The following formula can be used to estimate the focal length.
Focal length
=
WD /
(
1
+
W/w
)
WD
:
Working distance
(
distance between lens and object
)
W
:
Width of object
w
:
Width of sensor
②
Direct connection
(
or MP-43 tripod adapter plate
)
When mounting the camera directly to a wall or other device, use screws that match the
camera locking screw holes on the camera (M3, depth: 3 mm). Use the supplied screws to
attach the tripod adapter plate.
For heavy lenses, be sure to support the lens itself. Do not use configurations in which its weight
is supported by the camera.
Caution
③
LAN cable
Connect a LAN cable to the RJ-45 connector.
• Use a LAN cable that is Category 5e or higher (Category 6 recommended).
• Use a LAN cable that is STP cable.
• When supplying power via PoE, connect to a PoE-compatible switching hub or a PoE-compatible
network card.
•Refer to the specifications of the cable for details on its bend radius.
Secure the locking screws on the connector
manually, and do not use a driver. Do not secure
the screws too tightly. Doing so may wear down the
screw threads on the camera. (Tightening torque:
0.147 Nm or less)
Secure manually.
Do not secure too tightly.
④
Network card
Install this in the computer that will be used to configure and operate the camera. As the
camera supports PoE, you can also use PoE-compatible network cards. Refer to the
instruction manual of the network card, and configure settings on the computer as
necessary.
Caution
⑤
DC IN / trigger IN connection cable
⑥
AC adapter (power supply) (if necessary)
Connect the AC adapter and the round connector of the connection cable to the DC IN /
trigger IN connector on the camera.
Go-X Series GigE Vision I/F
Содержание Go-X Series
Страница 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79 ...
Страница 80: ... 80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F ...
Страница 81: ... 81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F ...
Страница 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82 ...
Страница 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83 ...
Страница 84: ... 84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F ...
Страница 88: ... 88 Revision Date Changes Revision history Go X Series GigE Vision I F ...