GO-5000M-USB-UV User Manual (Ver. 1.1)
Parts Identification
- 14 -
③
POWER/TRIG LED
Indicates the power or trigger input status.
LED
Status
Lit amber
Camera initializing
Lit green
Camera in operation
Blinking
green
During operation in trigger mode, trigger signals are being input.
Note:
The blinking interval is not related to the actual input interval of the external
trigger.
④
DC IN/TRIG Connector (6-Pin Round)
Connect the cable for a power supply (optional) or for DC IN / trigger IN here.
Camera Side: HR10A-7R-6PB (73) (Hirose Electric or equivalent)
Cable Side: HR10A-7P-6S (Plug) (Hirose Electric or equivalent)
Pin No.
Input/Output
Signal
Description
1
Power In
DC In
DC 10 V ~ 25 V
2
In
Opto In +
3
In
Opto In -
4
Out
Opto Out +
5
Out
Opto Out -
6
GND
GND
Note:
Refer to the
topic as well.
⑤
Camera Locking Screw Holes (M3, 3mm depth)
Use these holes when attaching an MP-43 tripod adapter plate (optional) or mounting the camera
directly to a wall or other structural system.