— 9 —
GO-2401M-PGE / GO-2401C-PGE
2
RJ-45 connector
Connect a Gigabit Ethernet compatible LAN cable (Category 5e or higher, Category 6
recommended) here.
Pin No.
Input/
output
Description
1
In/Out
MX1+ (DA+)
2
In/Out
MX1– (DA–)
3
In/Out
MX2+ (DB+)
4
In/Out
MX3+ (DC+)
5
In/Out
MX3– (DC–)
6
In/Out
MX2– (DB–)
7
In/Out
MX4+ (DD+)
8
In/Out
MX4– (DD–)
1
2
3
4
5
6
7
8
3
Power/trigger LED
Indicates the power and trigger input status.
4
ACT LED
Indicates the GigE network status.
5
LINK LED
Indicates whether the GigE network connection is 1000BASE-T or 100BASE-TX.
Operation with a 100BASE-TX connection is not possible. Always use 1000BASE-T.
LED status and camera status
LED
Light
Status
Power / trigger LED
Lit amber
Camera initializing.
Lit green
Camera in operation.
Blinking green
During operation in trigger mode, trigger signals are being
input.
The blinking interval is not related to the actual input interval
of the external trigger.
ACT LED
Lit amber
GigE network communication not established.
Blinking amber
GigE network communication in progress.
LINK LED
Lit green
1000BASE-T connection established.
6
DC IN / trigger IN connector (6-pin round)
Connect the cable for a power supply (optional) or for DC IN / trigger IN here.
1
2
3
4
5
6
HR-10A-7R-6PB (73) (Hirose Electric or equivalent)
Pin No.
Input/
output
Signal
Description
1
DC IN
+12 to +24 V
2
In
Opto IN 1
GPIO 5
3
Out
Opto OUT 1
GPIO 1
4
Out
Opto OUT 2
GPIO 2
5
Opto Common
6
GND