20
̶
GO-2400M-PMCL / GO-2400C-PMCL
5
If necessary, change the [Trigger Source], [Trigger Activation], and [Exposure Auto]
settings.
When controlling the exposure time using the pulse width of the trigger input signal
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
On
Trigger Source (trigger signal source)
Any
Trigger Activation (trigger polarity)
Level High (high-level duration), Level Low (low-level
duration)
Exposure Mode
Trigger Width (control via trigger width)
1
Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.