GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Main Functions
- 59 -
LUT (Lookup Table)
Related Setting Items:
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 256 setting
points (indexes).
To use the LUT function
Configure the settings as follows.
Item
Setting Value /
Selectable Range
Description
JAI LUT
Mode
LUT
Use LUT.
LUT
Selector
Red, Green, Blue
(Color model only)
Select the LUT channel to control.
LUT Index 0 ~ 255
Select the LUT index to configure. Indexes represent the setting points,
and values from the lowest point (Index 0) to the highest point (Index 15)
are represented. On the monochrome model, for example, Index 0 is full
black and Index 255 is full white.
LUT Value 0 ~ 4095
Set the LUT output value for the selected index.
Note:
For the color model, the same characteristic curve is configured for R, G, and B.
LUT values
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate
LUT values between the index points.