Setting List (Feature Properties)
- 86 -
Pulse Generators
Item
Setting Range
Default
Description
Pulse Generator Clear
Activation
Off
High Level
Low Level
Rising Edge
Falling Edge
0: Off
Set the clear signal condition for the count clear input of the
pulse generator.
Pulse Generator Clear
Source
Low
High
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
LVAL
User Output 0
User Output 1
Line4 - TTL In
Line7 - CC1
Nand0 Out
Nand1 Out
0: Low
Select the count clear input signal source. Line4 TTL In is
available on Standard Model.
Pulse Generator Clear
Inverter
True
False
0: False
Select whether to invert the polarity of the count clear input
signal.
Pulse Generator Clear
Sync Mode
Async Mode
Sync Mode
Async Mode Select the sync mode for the count clear input signal.
LUT Control
Related Topic:
Configure LUT settings.
LUT Control Item
Setting Range
Default
Description
LUT Selector
*Color Model Only
Red
Green
Blue
Green
Select the LUT channel to control.
LUT Index
0 ~ 255
0
Set the LUT index table number.
LUT Value
0 ~ 4095
0
Set the LUT index table number.