GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Settings List
- 83 -
LUTControl
Related Topic:
Configure LUT settings.
Note:
Settings that can only be configured when image acquisition on the camera is stopped.
LUT Control Item
Setting Range
Default
Description
LUT Selector
*Color models only
Red
Green
Blue
Green
Select the LUT channel to control.
LUT Index
0 ~ 255
0
Set the LUT index table number.
LUT Value
0 ~ 4095
0
Set the LUT value.
SequencerControl
Related Topic:
Configure sequencer settings.
Note:
Settings that can only be configured when image acquisition on the camera is stopped.
Sequencer
Control Item
Setting
Range
Default
Description
Sequencer Mode
Off
On
Off
Enable/disable Sequencer Mode.
Sequencer Mode
Select
Trigger
Sequencer
Mode
Command
Sequencer
Mode
Trigger
Sequencer
Mode
Select the Sequencer Mode.
Sequencer
Configuration Mode
Off
On
On
Select
On
to change the settings within the index.
Sequencer Set
Selector
1 ~ 128
1
Select the Trigger Sequencer mode and Command Sequencer mode index.
Sequencer Frame
Number
1 ~ 255
1
Set the number of frames to display for the selected Sequencer Index. (Enabled
only for Trigger Sequencer.)