EL-2800M-CXP / EL-2800C-CXP
- 34 -
The following diagrams show the Multi Frame Timing relationships.
Conditions:
Acquisition mode:
Multi
Trigger selector:
Acquisition Start
Acquisition Frame Count:
2
Trigger mode:
OFF
Fig.29 Multi Frame Timing (Acquisition Start OFF)
FVAL(Sensor Read
out)
Acquisition Trigger
Wait
Frame Trigger Wait
Acquisition
Active
Exposure
Active
Frame
Active
(Sensor
Exposure)
(Stream
Active)
Acquisition
Status
Output Signals
Acquisition Trigger
Wait = L
Frame Trigger Wait =
L
Acquisition
Active
Frame
Active
Exposure
Active
FALS
TRUE
FALSE
FALS
TRUE
FALS
TRUE
FALS
FALSE
FALSE
Acquisition Start
command
FALSE
TRUE
FALSE