5.5 Pulse Generator
The EL-2800-CXP has a frequency divider using the pixel clock as the basic clock and four pulse
generators. In each Pulse Generator, various Clear settings are connected to GPIO. The following
shows Pulse Generator default settings.
Table - 10 Pulse Generator default settings
5.5.1 Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit
length) and the pixel clock is used for this. Four built-in pulse generators work by the same
clock. In the EL-2800M/C-PMCL, the pixel clock is 108 MHz.
5.5.2 Pulse Generator Selector
This is where you select one of the 4 pulse generators in order to set or modify its parameters.
Table - 11
Pulse Generator setting
Display Name
Value
Clock Pre-scaler
1
Pulse Generator
Selector
Pulse Generator
Length
Start
Point
End
Point
Repeat
Count
Clear
Source
Clear
Inverter
Clear
Activation
Clear
Sync
Mode
-
Pulse Generator 0
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 1
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 2
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 3
1
0
1
0
Off
True
Off
Async Mode
Note:]
When Pulse
Generator Repeat Count is set to “0”, the camera is operating in Free Running mode.
However, based on the above default settings (Length=1, Start Point=0 and End Point=1), Pulse Generator stops at
High output. Therefore, if Start Point=0 and End Point=1 are configured, Length should be
“
2
”
as the minimum active
width.
Trigger Selector
item
Description
Pulse Generator
0
If Pulse Generator 0 is selected, Length
、
Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear Inverter, Clear Activation and Clear Sync Mode of pulse generator 0 are displayed under the
selector.
Pulse Generator
1
If Pulse Generator 1 is selected, Length
、
Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear Inverter, Clear Activation and Clear Sync Mode of pulse generator 1 are displayed under the
selector.
Pulse Generator
2
If Pulse Generator 2 is selected, Length
、
Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear Inverter, Clear Activation and Clear Sync Mode of pulse generator 2 are displayed under the
selector.
Pulse Generator
3
If Pulse Generator 3 is selected, Length
、
Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear Inverter, Clear Activation and Clear Sync Mode of pulse generator 3 are displayed under the