CV-M9 GE
- 13 -
6.4.2 Internal Trigger Generator
Create a trigger signal and trigger the camera
Address
Register
Value
0xA040
Trigger Mode
1 = EPS
0xB000
Clock Choice
1 = Pixel Clock
0xB004
Counter Dividing Value
963 = 1/964 dev(Line Rate)
0xB008
Length Counter 0
1000 Clocks
0xB00C
Start point Counter 0
100 Clocks
0xB010
Repeat Count 0
0 = Free Run
0xB014
End point Counter 0
500 Clocks
0xB018
Counter Clear 0
0 = No Clear
0xB058
CAMERA TRIG Selector
13 = pulse generator 0
LUT
(
Cross point switch)
LVAL IN
xTTL_LVDS Select
DVAL IN
FVAL IN
EEN IN
HIROSE TTL IN 1
HIROSE TTL IN 2
LVDS IN
HIROSE TTL IN 3
Soft Trigger 0
Pulse Generator 3
(20bit Counter)
Pulse Generator 2
(20bit Counter)
CAMERA TRIGGER
CAMERA Ext. VD
CAMERA Ext. HD
HIROSE TTL OUT 1
HIROSE TTL OUT 2
12bit
Counter
25MHz
Pixel Clock
Pulse Generator 1
(20bit Counter)
Pulse Generator 0
(20bit Counter)
Line Rate 37.5KHz
LUT
(
Cross point switch)
LVAL IN
xTTL_LVDS Select
DVAL IN
FVAL IN
EEN IN
HIROSE TTL IN 1
HIROSE TTL IN 2
LVDS IN
HIROSE TTL IN 3
Soft Trigger 0
Pulse Generator 3
(20bit Counter)
Pulse Generator 2
(20bit Counter)
CAMERA TRIGGER
CAMERA Ext. VD
CAMERA Ext. HD
HIROSE TTL OUT 1
HIROSE TTL OUT 2
LUT
(
Cross point switch)
LVAL IN
xTTL_LVDS Select
DVAL IN
FVAL IN
EEN IN
HIROSE TTL IN 1
HIROSE TTL IN 2
LVDS IN
HIROSE TTL IN 3
Soft Trigger 0
Pulse Generator 3
(20bit Counter)
Pulse Generator 2
(20bit Counter)
CAMERA TRIGGER
CAMERA Ext. VD
CAMERA Ext. HD
HIROSE TTL OUT 1
HIROSE TTL OUT 2
12bit
Counter
25MHz
Pixel Clock
Pulse Generator 1
(20bit Counter)
Pulse Generator 0
(20bit Counter)
Line Rate 37.5KHz
12bit
Counter
25MHz
Pixel Clock
Pulse Generator 1
(20bit Counter)
Pulse Generator 0
(20bit Counter)
Line Rate 37.5KHz
Pulse Generator 0
100 Line
500 Line
1000 Line
output
Pulse Generator 0
100 Line
500 Line
1000 Line
output
Pulse Generator 0 timing