CV-L108CL
8
Connector 2 ( Used only for 3 x 10 Bit output)
Pin No
In/Out
Name
Note
1,14
Shield
GND
2(-),15(+)
O
TxOUT0
Data out
3(-),16(+)
O
TxOUT1
4(-),17(+)
O
TxOUT2
5(-),18(+)
O
TxClk
Clock for CL
6(-),19(+)
O
TxOUT3
Data out
7(+),20(-)
N.C
8(-),21(+)
N.C
9(-),22(+)
N.C
10(+),23(-)
N.C
11,24
N.C
12,25
N.C
13,26
Shield
GND
The CV-L108CL follows the Camera Link standard in all respects.
Please refer to the Camera Link version 1.1 specifications for detailed information on bit
assignments of 24-bit RGB and 30-bit bit output.
5.3.
Input and output circuits
5.3.1.
Trigger input
The External Trigger signal can be applied either through the Camera Link connector or at pin 10 of
the 12-pin Hirose connector. The command to change this setting is TI (Trigger Input). TI=0 for
Camera Link connector (factory default) and TI=1 for 12-pin Hirose connector. The input via the
12-pin Hirose connector is AC coupled.
To allow long pulses, which may be required when using the Pulse Width Control (PWC) trigger
mode, the input circuit is designed as a flip-flop circuit. The leading and trailing edges of the trigger
pulse activate the circuit.
The trigger input polarity can be changed by the command TP. At the 12-pin Hirose connector the
External Trigger input is 4V ± 2V (TTL). It can be changed to 75 ohm termination by an internal
switch setting (SW 801-2).
Fig. 4 Trigger input (12-pin Hirose)