CM-030GE/CM-030GE-RA / CB-030GE/CB-030GE-RA
- 25 -
7.5.3 Partial Scanning
The FVAL period is shown for 1/2 partial scan in normal continuous mode.
7.5.3.1 Vertical Timing
The below diagram and table provide vertical timing information for the fixed partial scan
settings 1/2, 1/4, 1/3 and 2/3
LVAL
FVAL
DVAL
DATA
EEN
Valid Data
CCD Exposure
A
B
C
7L
1L
Valid Data
Values for vertical timing in partial scan continuous mode.
Fig. 21. Vertical timing for partial scanning
AREA
FVAL
Low (L)
A
(L)
B (L)
C
(L)
Total
line
(L)
frame
rate
(fps)
Start line End line
1/2
7
19
246
18L
290L
159.64
125
370
1/4
7
26
122
26L
181L
255.75
187
308
1/8
7
30
62
29L
128L
361.68
217
278
2/3
7
14
326
13L
360L
128.6
85
410