6. Input and output interface
6.1. GPIO interface
All input and output signals pass through the GPIO (General Purpose Input and Output) module.
The GPIO module consists of a Look-Up Table (LUT – Cross-Point Switch), 4 Pulse Generators
and a 12-bit counter. In the LUT, the relationship between inputs, counters and outputs is
governed by internal register set-up.
LUT
( Cross Point Switch )
Pulse Generator 1
(20 bit Counter )
Pulse Generator 0
(20 bit Counter )
12 bit
Counter
TRIGGER 0
TRIGGER 1
PORT 1 1
PORT 2
Time Stamp Reset
LVAL IN
DVAL IN
FVAL IN
EEN IN
OPT IN 1
OPT IN 2
Soft Trigger 0
Soft Trigger 1
Soft Trigger 2
Soft Trigger 3
IN
OUT
Pulse Generator 0
Pulse Generator 1
Pulse Generator 0
Pulse Generator 1
Digital I/O(GPIO) setting
0
1
2
3
4
5
12
13
14
15
16
17
Digital I/O(GPIO) setting
0
1
4
5
16
12
13
Setting for
Line Source
Setting for
Line Selector
25 MHz
Pixel Clock
Counter Clock Source
0
1
Counter Divide by value
1/2 to 1/4096
Bypass
0
1 - 4095
Pulse Generator Setting 0
Start Point Counter 0 ( 1)
Length counter 0
Start Point Counter 0 (2) for repeat
End point counter 0
Counter 0 clear
Pulse Generator Setting 1
Pulse Generator 1
Pulse Generator 1
18
19
Pulse Generator 2
Pulse Generator 3
14
15
Pulse Generator Setting 2
Pulse Generator Setting 3
Pulse Generator 2
(20 bit Counter )
Pulse Generator 3
(20 bit Counter )
Fig.6 GPIO block
The input and output settings for the CM-030GE and CB-030GE series have been fixed as
follows.
Line
Signal
Connector
Line 3
Optical Out 1
Hirose 12P pin # 7/8
Line 4
Optical Out 2
Hirose 12P pin # 9/10
Line 5
Optical In 1
Hirose 12P pin # 5/6
Line 6
Optical In 2
Hirose 12P pin # 3/4
6.1.1 LUT (Look Up Table)
The LUT works as a cross-point switch, which allows connecting inputs and outputs freely.
The signals LVAL_IN, DVAL_IN, FVAL_IN and EEN_IN all originate from the camera timing
circuit.
Trigger 0 is connected to the camera's timing circuit and is used for initiating triggered
exposure. Trigger 1 is used for Delayed Readout mode. The Time Stamp Reset signal is used
reset the camera's time stamp function, also making it possible to reset and synchronize the