AD-081CL
- 35 -
7.4
Modes and functions matrix
AD-081CL has two output modes when the external trigger pulse is used. One is “Synchronous”
mode and the other is “Separate” mode. In Synchronous mode, two Camera Link outputs are
synchronized with each other, whereas in Separate mode, two Camera Link outputs are not
synchronized.
The following table shows modes and functions matrix.
BW1 Imager ( 1)
BW2 imager (2)
Output
mode
IS=
Operation
Trig.
IN 1
Shutter Partial Smear
Less
TRIG.
IN 2
Shutter Partial Smear
Less
Auto
Iris
TR Mode
゙
IS=0
Sync
0
Cont. −
Yes
Yes
No
−
Yes
No
Yes
Note
1
PS
Yes Yes
Yes
Yes
No
Yes
2
PW
Yes No
Yes
Yes
No
No
IS=1
Separate
0
Cont. −
Yes
Yes
No
−
Yes
Yes
No
Yes
Note
1
PS
Yes Yes
Yes
Yes
Yes
Yes
Yes
Yes
2
PW
Yes No
Yes
Yes
Yes
No
Yes
Yes
−
4
PIV1
Yes No
Yes
No
−
−
−
−
5
PIV2
Yes No
Yes
No
−
−
−
−
6
PIV3
Yes No
Yes
No
−
−
−
−
− : not related to ,
:
Use BW1 imager (1) setting
Note: The analog output for auto iris uses the signal from BW1 imager (1).