Technical Specifications
Item no. 13404080, Revision 01
21 ( 40 )
6.5
Tool change monitoring
Tool taper monitoring indicates the readiness status of the HF spindle to the
operator and forwards the corresponding signal to the machine controller.
q
Tool taper monitoring using inductive proximity switch.
Signals
Tool clamped
Tool ejected
HF spindle
HF spindle
Ready to operate
Not ready to operate
Operating voltage range:
10-30 VDC (UL – Class 2)
Switching distance: Sn 2.0 mm
Short-circuit and reverse-po-
larity resistant.
PNP
BK (4)
BU (3)
BN (1)
Z
+
Output
0 V
BN = brown
BK = black
BU = blue
NO = Normally ope
6.6
Speed sensor (digital differential magneto resistor)
Trouble-free evaluation requires good wiring.
Ü
Use twisted and shielded cables.
Ü
Connect the HF spindle based on the connection example shown below.
DFP = digital differential magneto
resistor
S = signal
Note: Resistor (Rx).
If the resistor (Rx*) is already integrated in the evaluation unit (FC):
u
Only connect signal and ground.
Supply voltage (U)
Rx (*)
Signal (**)
+ 8 V
220 Ω
1000 mV
+ 8 V
450 Ω
2000 mV
+ 12 V
220 Ω
1000 mV
+ 12 V
680 Ω
3000 mV
+ 15 V
220 Ω
1000 mV
+ 15 V
680 Ω
3000 mV
+ 24 V
220 Ω
1000 mV
+ 24 V
680 Ω
3000 mV
*Unnecessary if a resistor is integrated in the evaluation unit (frequency converter, etc.).
**Values may differ by ±20% depending on the measuring method.