Technical Specifications
Item no. 10405047-08, Revision 00
18 ( 48 )
6.3
Wiring diagram
Note: Do not change the ex-works configuration.
Any change may cause overvoltage on the electrical components (e.g. PTC,
differential magneto resistor).
UB+
+5V
GND
UN+
UA-
UA+
UB-
UN-
GND
Sense
Zahnradgeber GEL 2442
precision encoder GEL 2442
1
2
5
9
10
11
12
13
14
16
3
4
6
7
8
15
17
PK
0,25 mm²
RD
0,25 mm²
BU
0,25 mm²
GY
0,25 mm²
BN
0,25 mm²
WH
0,25 mm²
BK
0,25 mm²
GN
0,25 mm²
YE
0,25 mm²
Kabelstecker SA17 (S10)
male cable connector SA17 (S10)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Rückseite
back side
Kundenseite
customer side
Kundenseite
customer side
UA+ Spur A
UA+ track A
UA- Spur A
UA- track A
UB- Spur B
UB- track B
UB+ Spur B
UB+ track B
Nullspur UN-
reference UN-
Nullspur UN+
reference UN+
Versorgungsspannung
supply voltage
+5V (+/-5%)
Brücke zu Pin 5 (Masse)
jumper to pin 5 (earth)
Versorgungsspannung Masse
supply voltage earth
Sense
2.0
1
Perschewski
17.05.17
1
29025970
g
f
e
d
c
b
a
4
5
6
1
3
2
a
b
c
d
e
f
g
Bl.
Übersetzungen, Vervielfältigungen und die Weitergabe an Dritte, auch nur auszugsweise,
ist ohne schriftliche Gehnehmigung der Fa. Nakanishi Jaeger GmbH untersagt
Datum
Gepr.
Bearb.
Norm
Projekt Nr.:
Version Nr.:
Zeichn.Nr.:
von
Blatt
DIN 81346
Pinbelegung FS17 (S10) Vektor Sense
(Fa. Sauer)