background image

Technical Specifications

Item no. 10203039, Revision 06

18 ( 36 )

6.5

Speed sensor (digital differential magneto resistor)

Trouble-free evaluation requires good wiring.

Ü

Use twisted and shielded cables.

Ü

Connect the HF spindle based on the connection example shown below.

DFP = digital differential magneto

resistor

S = signal

Note: Resistor (Rx).

If the resistor (Rx*) is already integrated in the evaluation unit (FC):

u

Only connect signal and ground.

Supply voltage (U)

Rx (*)

Signal (**)

+ 8 V

220 Ω

1000 mV

+ 8 V

450 Ω

2000 mV

+ 12 V

220 Ω

1000 mV

+ 12 V

680 Ω

3000 mV

+ 15 V

220 Ω

1000 mV

+ 15 V

680 Ω

3000 mV

+ 24 V

220 Ω

1000 mV

+ 24 V

680 Ω

3000 mV

*Unnecessary if a resistor is integrated in the evaluation unit (frequency converter, etc.).

**Values may differ by ±20% depending on the measuring method.

6.6

ESD protection

ESD protection is provided by creating an electrically conductive connection
between the rotating shaft of the HF spindle and the motor housing.

q

Depending on the operating time, the electrical resistance of this sliding
contact is <1 kΩ.

q

The wear on the sliding contact is not monitored.

Содержание Z62-M360.52 S5AM

Страница 1: ...Manual Z62 M360 52 S5AM High Frequency Spindle Manual tool change...

Страница 2: ...velopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Al fr...

Страница 3: ...eed sensor digital differential magneto resistor 18 6 6 ESD protection 18 6 7 Air borne noise emissions 19 7 Operating location 19 8 Installation 20 8 1 Installing the HF spindle 20 8 2 Diameter of me...

Страница 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Страница 5: ...es Available on request q Spindle holder q Frequency converter q Chiller q Collet q Felt cleaning taper q Collet grease q Further accessories on request Only approved accessories have been tested for...

Страница 6: ...ol and a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Alfred...

Страница 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Страница 8: ...ause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure fun...

Страница 9: ...to the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a...

Страница 10: ...Technical description Item no 10203039 Revision 06 10 36 5 Technical description 5 1 Connections of HF spindle 2 1 3 2 1 Electrical connection 2 Cooling water G 1 8 3 Sealing air G 1 8...

Страница 11: ...the machine con troller Note Connect the SpeedTEC quick locking connector u For the combination SpeedTEC connector plug SpeedTEC cable plug u Remove the O ring on the SpeedTEC connector plug 5 3 Cooli...

Страница 12: ...oles pairs 1 Rated rotation speed 60 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor Number of signals...

Страница 13: ...Technical Specifications Item no 10203039 Revision 06 13 36 6 1 Dimensions Clamping range...

Страница 14: ...04 22 856 27 860 37 684 47 509 56 761 rpm Frequency 167 250 333 417 500 667 833 1 000 Hz Rated power 0 192 0 289 0 419 0 524 0 633 0 853 1 044 1 249 kW Torque 0 21 0 21 0 22 0 22 0 22 0 22 0 21 0 21 N...

Страница 15: ...078 1 243 1 808 2 076 2 503 kW Torque 0 48 0 479 0 452 0 473 0 432 0 474 0 425 0 428 Nm Voltage 68 93 111 128 149 184 214 249 V Current 10 10 4 10 6 10 5 10 9 11 10 5 10 6 A Cos 0 89 0 84 0 83 0 82 0...

Страница 16: ...c d e f g Bl bersetzungen Vervielf ltigungen und die Weitergabe an Dritte auch nur auszugsweise ist ohne schriftliche Gehnehmigung der Fa Alfred J ger GmbH untersagt Datum Gepr Bearb Norm Projekt Nr V...

Страница 17: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Страница 18: ...ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000 mV 15 V 680 3000 mV 24 V 220 1000 mV 24 V 680 3000 mV Unnecessary if a resistor is in...

Страница 19: ...G Risk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always we...

Страница 20: ...se fittings Make sure that the connections are flexible and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal all connections for cooling wate...

Страница 21: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Страница 22: ...n air quality see Air purity classes ISO 8573 1 22 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Страница 23: ...entrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Turn the shaft of the spindle at least ten times by...

Страница 24: ...the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage location to the t...

Страница 25: ...Use the hook wrench to unfasten the clamping nut and the collet Make use of the hook wrench from the scope of delivery of the HF spindle Remove the tool Screw the clamping nut out Remove the collet f...

Страница 26: ...out u Only use tools with the correct direction of rotation for the HF spindle DANGER Due to flying parts If the speed is selected incorrectly the HF spindle or the tool may be de stroyed and their fr...

Страница 27: ...rings u Do not apply grease oil or cleaning agents to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF s...

Страница 28: ...the HF spindle in horizontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage l...

Страница 29: ...ction More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non re...

Страница 30: ...al energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the...

Страница 31: ...er See also Spindle becomes hot 31 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q C...

Страница 32: ...ruly or is dis torted q Only use spindle holders from the original accessories or holders produced according to the tolerances specified by Alfred J ger GmbH HF spindle clamped too tightly q Only tigh...

Страница 33: ...Observe all points in the Tool change 25 and Mainte nance 27 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machini...

Страница 34: ...receipt of the product No liability is accepted for damage caused by the following Unsuitable or non designated use incorrect installation or commissioning by the customer or third parties natural wea...

Страница 35: ...1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized standards DIN EN ISO 12100 S...

Страница 36: ...Ober M rlen GERMANY 49 0 6002 9123 0 sales alfredjaeger de www alfredjaeger de Serial number Spindle type Z62 M360 52 S5AM Item no 10203039 Revision 06 Date 04 06 2018 Language EN Jaeger Spindles Nor...