Installation
Item no. 10403015, Revision 03
25 ( 40 )
8.4.3
Setting values
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
Ü
Keep to the following values:
Taper cleaning
4,5 - 6 bar
Pneumatic system for tool change
≥ 6,0 bar
8.5
Protection category IP65
To operate the HF spindle with a protection category of IP65, the following
points must be observed:
Ü
Connect the vent for the cylinder.
The cylinder takes in air when clamping the taper/tool.
Ü
Select the length of the hose so that its end protrudes out of the area re-
quired according to IP65 far enough that no dirt or moisture can be taken
into the hose.
Ü
The hose connection must conform to IP65 at minimum.
Ü
Attach an additional filter on the end of the hose.
Ü
Turn on the sealing air.
Ü
The connecting cable with the current and control cables must be compli-
ant with at least IP65.
Ü
Make sure that the connection cable is attached and securely locked.