background image

Tool change

Item no. 10405044, Revision 10

34 ( 44 )

10.4.2

Electrical workflow

Tool taper

Compressed air on

Clamped

Released

Ejected

Not 

inserted

Yes

No signal

= 0

Signal

= 1

No signal

= 0

Inserted

Yes

Signal

= 1

No signal

= 0

No signal

= 0

Not 

clamped

Yes

No signal

= 0

No signal

= 0

Signal

= 1

10.4.3

Signals

Inputs

Description

Signal

Action

Released

signal

Cylinder back. 
Clamping system released.

No

 tool taper inserted in tool mount

of HF spindle.

= 0

Do not start

HF spindle

Clamped

signal

Cylinder back. 
Clamping system clamped

 with tool.

Tool taper inserted in tool mount of
HF spindle.

= 1

Start HF spindle
when signal = 1

Ejected

signal

Cylinder is extended. 
Clamping system disengaged.
Tool taper inserted in tool mount of
HF spindle.
Tool taper is 

not

 clamped here.

= 0

Do not start

HF spindle

Note: Ensure functionality.

The “released” signal shows the user the ready state of the HF spindle in or-
der to ensure safety during operation.

The “released” clamp status is:

q

not a permissible operating status

q

only permissible during transport and storage

Every idle stroke shortens the service life of the HF spindle.

Содержание Z100-H530.05 S11W2

Страница 1: ...Manual Z100 H530 05 S11W2 High Frequency Spindle Pneumatic taper change...

Страница 2: ...opment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanish...

Страница 3: ...ions 24 7 Operating location 24 8 Installation 25 8 1 Installing the HF spindle 25 8 2 Diameter of media supply line 26 8 3 Cooling water 26 8 3 1 Quality of cooling water 26 8 3 2 Setting the cooling...

Страница 4: ...Item no 10405044 Revision 10 4 44 Contents Translation of the original manual 14 Service and repairs 39 14 1 Service partners 39 14 2 Malfunctions 40 15 Declaration of Incorporation 43...

Страница 5: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Страница 6: ...accessories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Hose connections q Further accessories on request Only approved accessories have been tested for ope...

Страница 7: ...nd a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi J...

Страница 8: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Страница 9: ...ay cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure...

Страница 10: ...arding this to the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft h...

Страница 11: ...of HF spindle 1b 3 2 1a 2 4 7 8 1a Electrical connection for motor phases 1b Electrical connection for Tool taper monitoring PTC 2 Cooling water G 1 4 3 Sealing air G 1 8 4 Taper cleaning G 1 8 7 Pne...

Страница 12: ...ormation The FC detects the following operating states of the HF spindle depending on the version q HF spindle rotating q HF spindle too hot q HF spindle at a standstill etc The FC forwards the operat...

Страница 13: ...pindle 5 5 Taper cleaning For guidelines on air quality see Air purity classes ISO 8573 1 27 section Taper cleaning prevents chips and liquids from entering the shaft during a tool change and causing...

Страница 14: ...oles pairs 2 Rated rotation speed 30 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Motor protection PTC 130 C Housing Stainless steel Housing di...

Страница 15: ...Technical Specifications Item no 10405044 Revision 10 15 44 Inner taper run out 1 Axial run out 1 6 1 Dimensions Clamping range...

Страница 16: ...ax S1 Measured values S1 100 Rated rotation speed 5 000 10 000 15 000 20 000 25 000 30 000 rpm Speed 4 760 9 650 14 675 19 680 24 685 29 750 rpm Frequency 167 333 500 667 833 1 000 Hz Rated power 0 91...

Страница 17: ...0 12 kW Torque 4 7 4 7 4 1 4 1 4 1 3 9 Nm Voltage 85 140 210 260 320 380 V Current 28 28 28 28 28 28 A cos 0 82 0 72 0 76 0 71 0 69 0 75 Note on operation with static frequency converters For operatio...

Страница 18: ...7 16 Arms p0322 Maximum speed 42 000 rpm p0326 Stalling torque correction factor 100 p0335 Cooling type Liquid cooled p0341 Moment of inertia 0 001 kgm p0348 Field weakening operating speed VDC 600V...

Страница 19: ...pol 8 1 11 4pol 3 7 4pol 4 7 2pol 2 7 2pol Motorvarianten Kundenseite customer side R ckseite back side 1 2 3 4 PE Schutzleiter protective earth Kundenseite customer side phase U phase V phase W Achtu...

Страница 20: ...0V BK BU 3 4 PNP Spindelstecker S12 ECTA S13 spindle plug S12 ECTA S13 BN 1 Vs output 0V BK BU 3 4 PNP BN 1 Vs output 0V BK BU 3 4 PNP C BN 0 14mm BU 0 14mm BK 0 14mm BK 0 14mm BK 0 14mm PTC BU 0 14mm...

Страница 21: ...TA S11 cable socked GB5 ECTA S11 GNYE 6mm BK1 6mm BK2 6mm BK3 6mm Motorkabel 4x6mm motor cable 4x6mm 2 0 1 Perschewski 24 10 17 1 Motorkabel GB5 29006740 g f e d c b a 4 5 6 1 3 2 a b c d e f g Bl ber...

Страница 22: ...control cable 4x 2x0 38mm 4x0 5mm Kabeldose GB12 ECTA S13 cable socked GB12 ECTA S13 2 0 bis 2015 up to 2015 1 Perschewski 24 10 17 1 Motorkabel GB12 29007040 g f e d c b a 4 5 6 1 3 2 a b c d e f g...

Страница 23: ...st voltage Vis 3 kV Response time ta 2 5 s Operating temperature range V 0 Top 25 180 C Resistance values TNAT T R TNAT T VPTC 2 5 V R TNAT T VPTC 2 5 V R TNAT 15 K VPTC 7 5 V R TNAT 23 K VPTC 2 5 V 1...

Страница 24: ...G Risk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always we...

Страница 25: ...corresponding hoses in the hose fittings Make sure that the connections are flexible and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal al...

Страница 26: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Страница 27: ...n air quality see Air purity classes ISO 8573 1 27 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Страница 28: ...le without a clamped tool shank If no tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q Th...

Страница 29: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Страница 30: ...q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged 10 1 Clockwise and counter clockwise Sa...

Страница 31: ...free of damage and clean when switching to the HF spindle Insert the tool up to the contact surface of the clamping taper Make sure that the shaft of the HF spindle has come to an absolute stand stil...

Страница 32: ...eumatic taper change During a tool change the tool mount is pressed out of the shaft by the cylin der 10 3 2 Installing the changing station Proceed as follows to install the changing station Drill a...

Страница 33: ...Tool change at the HF spindle Caution No rotation without clamped tool Tool clamped signal HF spindle is ready for use No Connection on off Compressed air Always leave sealing air switched on Even in...

Страница 34: ...t HF spindle Clamped signal Cylinder back Clamping system clamped with tool Tool taper inserted in tool mount of HF spindle 1 Start HF spindle when signal 1 Ejected signal Cylinder is extended Clampin...

Страница 35: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Страница 36: ...curately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air...

Страница 37: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Страница 38: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Страница 39: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Страница 40: ...equency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Tro...

Страница 41: ...damaged q Contact Nakanishi Jaeger GmbH service No automatic tool change Cause Troubleshooting Contamination q Remove all contamination between the tool taper and shaft of the HF spindle Observe all...

Страница 42: ...serve all points in the Tool change 30 and Mainte nance 36 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Страница 43: ...5 1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized sta...

Страница 44: ...len GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z100 H530 05 S11W2 Item no 10405044 Revision 10 Date 01 09 2023 Language EN Jaeger Spindles North A...

Отзывы: