Maintenance
Item no. 10503007, Revision 03
30 ( 36 )
12.2.3
Every time the clamping device is changed
Ü
Clean the inner taper of the HF spindle shaft. The inner taper must be free
of chips and contamination.
Ü
Clean the tool taper.
Ü
Apply a light greasy film to the taper of the collet after cleaning.
Ä
Only use the collet grease from the service set.
This improves the sliding movement and increases the clamping force of the
collet.
12.3
In the case of storage
If the HF spindle is not required for a prolonged period of time:
Ü
Before storing and before commissioning only clean the cooling duct with
compressed air.
Ü
Remove all coolant residues.
Ü
Store the HF spindle in horizontal position.
Ü
Store the HF spindle so that it is protected from moisture, dust, and other
environmental influences.
Ü
Note the following storage conditions.
Temperature of storage location
+10°C … + 45° C
Relative humidity
< 50 %
12.4
Monthly maintenance
Ü
Turn the shaft of the HF spindle at least ten times by hand every four
weeks.
12.5
Long periods of storage
Ü
Turn the shaft of the HF spindle at least ten times by hand every three
months.
Ü
Then put the HF spindle into operation with a tool inserted for approx.
10 minutes.
Ä
The speed should be no more than 20 % of the maximum permissible
speed for the HF spindle. (See Commissioning
section)
12.6
Maximum storage time
The maximum storage time is 2 years.
Ü
Make sure that all information in the "Long periods of storage
tion is adhered to. This is the only way in which to maintain the functional-
ity of the HF spindle.