complete
systems
for
digital
modes
E-Mail:
jäger
computing
&
services
Tel.
+49
(0)
6184
9520018
D-63517 Rodenbach Weidertsweg 8 GERMANY
http://www.jaeger-edv.de
Copyright © 2006-2016 Jäger EDV & Dienstleistungen
- 3 -
Instructions for initial start-up of the I-GATE.
Changed settings must be saved on each page. (save)
To save the settings permanently, click to the „restart“ tab and click then to “save permanent and
restart”.
NOTE: If TRX modules are installed, always connect the antenna or a dummy load.
1.0
Tab Overview
Most parameters are preset at the time of delivery. (d
efault
)
1.1 Apply a DC voltage between 8-15 volts / 200 mA to
barrel connector socket 5,5 x 2,1 /2,5 mm and switch on.
1.2 The display is now active and displays various information consecutively.
1.3 Wait for the network settings page to appear and read the IP. (2nd line left)
1.4 Enter the IP into the browser. You will get immediate access to the I-GATE.
1.5 In order to open the tab 2 to 15 a password is required.
1.5 As basic settings enter here “
admin”
and
”password”.
Please change the password.
2.0
Tab Comm
Go to
presets
and select there a preset kiss device,
Use the same baud rate as used for KISS device.
3.0
Tab Modem
Go to
intern modem
and select 300 baud for short wave or 1200 baud for
VHF.
3.1 For TRX1 or TRX2 (option) set frequency and baud rate 1200 or 9600 baud.
4.0
Tab station
Enter
call, latitude and longitude from APRS.FI and
check entries. The locator is automatically calculated according to
save
.
4.1 Customize beacon comments for own texts. Set schedule day and time.
4.2 Select icon and enter status text.
4.3 Enter radio time interval for sending via HF. (distance less than 10 minutes will be locked)
4.4 Enter internet time interval for sending via the internet.
5.0
Tab I-GATE
the servers are from top to bottom. If necessary, add server.
5.1 Enter validation number. Registration required
http://www.apritch.myby.co.uk/uiv32.htm
5.2 EXTRA log on text for example: Filter m/15 b/call/call p/D/VE/P (this entry is optional).
6.0
Tab Digipeater
Enter
wide1-1,wide2-2
as path entries. No APRS, no relay, no trace!
6.1 TRX1 Module 2m (option) for 1200 baud or 9600 baud.
6.2 TRX2 module 70cm (option) for 1200 / 9600 baud. (usable as frequency discharge module)
6.3 Waterfall spectrum from audio frequency spectrum as optical adjustment aid for RX on 30m/
20m-band.
6.4 Set routing I-GATE filter. (firmware is here revised)
7.0
Tab Network
Enter station call and port entries, I-GATE is also accessible via browser.
7.1 Check port and release with call in your own router, Change password and write it down.
7.2 Assign Fixed IP, In this case a password will be requested.
8.0 T
ab Dynamic DNS
Enter
r
emote maintenance data so that the I-GATE can be contacted
worldwide.
9.0
Tab mail
Enter here your E-mail address. (no SSL)
10.0
Tab WX
Select Weather Station Setup. Enter latitude and longitude,
10.1 Select send option and select time interval for sending weather data