background image

   3

JAGA NV   |   BRIZA 22 - JDPC.002 - US |  MANUAL  |  27200.20000096  |  11.02.2021   |   V.02

EN

Important info

The unit must be installed by a certified installer in accordance with the installation 

instructions and the local building codes. Please follow this instruction manual and 

file it somewhere safe! The unit must always be accessible for maintenance and 

inspection.

The warranty is void when:

-  the installation, maintenance or operation instructions in this manual are not respected.

-  modifications have been made to the product,before, during or after product installation.

-  maintenance has been carried out by unauthorized people.

-  maintenance has been carried out by someone other thanJaga.

-  access to the unit has been restricted due to on-site conditions.

-  the initial start-up has been carried out before a general cleaning of both the fan and the coil. 

1. OVERVIEW ....................................................................................................................... 4

A. WATER TEMPERATURE SENSOR ONLY .....................................................................................................4
B. WATER AND ROOM TEMPERATURE SENSOR..........................................................................................5

2. SETTINGS VIA CIRCUIT BOARD CONTROLLER .................................................... 6
3. WARRANTY CONDITIONS ........................................................................................... 8
4. DISSASSEMBLY INSTRUCTIONS ............................................................................... 8

CONTENT

DECLARATION OF CONFORMITY 

JAGA N.V. - Verbindingslaan 16  - B 3590, declares under its sole responsibility that the 

product to which this declaration relates:

is in conformity with the following standards or documents provided that these are used in 

accordance with our instructions:

Following the provision of Directives as amended:

JDPC.002

- Low Voltage 2014/35/EC

- EMC 2014/30/EC

- Machinery 2006/42/EC

 

 

                    NBN EN 60335-1 based on EN 60335-1:2012 + A11:2014 

NBN EN 60335-2-80 based on EN 60335-2-80:2003 + A 1 :2004 + A2:2009

CEO JAGA N.V.

Jan Kriekels

31/03/2017

Содержание BRIZA 22 -JDPC.002

Страница 1: ...BRIZA 22 JDPC 002 INSTRUCTIONS D INSTALLATION INSTALLATION INSTRUCTIONS ...

Страница 2: ...EN FR PG 3 PG 9 2 ...

Страница 3: ...e unit has been restricted due to on site conditions the initial start up has been carried out before a general cleaning of both the fan and the coil 1 OVERVIEW 4 A WATER TEMPERATURE SENSOR ONLY 4 B WATER AND ROOM TEMPERATURE SENSOR 5 2 SETTINGS VIA CIRCUIT BOARD CONTROLLER 6 3 WARRANTY CONDITIONS 8 4 DISSASSEMBLY INSTRUCTIONS 8 CONTENT DECLARATION OF CONFORMITY JAGA N V Verbindingslaan 16 B 3590 ...

Страница 4: ...x A WATER TEMPERATURE SENSOR ONLY Configuration code DPC BR21 DPC BR22 1 2P 4P N L Line voltage Not used WHITE BLACK 24VDC 120V 60Hz Standard 208V 60Hz HP 2 A 1 FACTORY SETTINGS The unit is controlled by the water temperature The unit starts when the preset water temperature is reached The unit starts when the water temperature 28 C 82 F Only with configuration code DPC BR22 The unit starts when t...

Страница 5: ...atically switch to standby The device automatically enters heating mode when the water temperature is 4 C 7 F above the room temperature If the differential between room and water temperature is less than 1 C 2 F higher than the room temperature the device will automatically switch to standby 1 2P 4P N L Line voltage Not used WHITE BLACK 24VDC 120V 60Hz Standard 208V 60Hz HP C B 1 FACTORY SETTINGS...

Страница 6: ...ater temperature 1 Start setup mode Press and hold the button until the red LED flashes 5x and release 2 Short press the or button to adjust the set temperature 53 F 57 F 61 F 64 F 68 F 71 F 75 F 79 F 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C TheblueLEDflashesquicklywhen the minimum temperature is reached TheblueLEDflashesquickly when the mini mum temperature is reached The red LED flashes quickly w...

Страница 7: ...nthe minimum speed is reached The red LED flashes quickly when the maximum speed is reached 1 10 sec 1 2 4 FACTORY RESET 1 Disable power charge 2 Press and hold down both the and button on the circuit board and switch on the power again The blue LED will light up followed by the green LED 2 seconds later and the red LED 4 seconds later Release the buttons as soon as all 3 LEDs are flashing 3 The c...

Страница 8: ...oduct is not accessible for cleaning or maintenance If you have any questions or complaints please contact your supplier or installer The copyright of these instructions is the property of Jaga 4 DISSASSEMBLY INSTRUCTIONS SAFEGUARD THE ENVIROMENT Jaga cares about protecting the environment When the unit is dismantled it is important to strictly follow these procedures the unit must be dismantled b...

Страница 9: ... des instructions de montage de nettoyage ou d utilisation du fabrikant Une utilisation et ou traitement incorrect e inapproprié e et ou irresponsable de l appareil Réparations incorrectes ou incompétentes et pannes dues à des facteurs externes À des réparations effectuées soi même à l appareil appareils montés de telle manière qu ils ne sont pas aisément accessibles Cet appareil est soumis aux co...

Страница 10: ... DE LA TEMPÉRATURE D EAU Code de configuration DPC BR21 DPC BR22 1 2P 4P N L Line voltage Not used WHITE BLACK 24VDC 120V 60Hz Standard 208V 60Hz HP 2 A 1 RÉGLAGES EN USINE L appareil est commandé par la température de l eau L appareil se met en marche dès que la tem pérature de l eau définie est atteinte L appareil se met en marche dès que la température de l eau 28 C 82 F Uniquement avec code de...

Страница 11: ...iquement en standby L appareil passe automatiquement en mode chauffage dès que la température de l eau est de 4 C supérieure à la température ambiante Lorsque la différence de température d eau est inférieure de 1 C au dessus la température ambiante l appareil se remet automatiquement en standby 1 2P 4P N L Line voltage Not used WHITE BLACK 24VDC 120V 60Hz Standard 208V 60Hz HP C B 1 RÉGLAGES EN U...

Страница 12: ...a température de l eau à un niveau inférieur 1 Régler le démarrage enfoncez le bouton du circuit imprimé jusqu à ce que le LED rouge cligno te 5x et relâchez 2 Appuyez brièvement sur le bouton ou pour ajuster la température réglée 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C LeLEDbleuclignoterapidement une fois la themperature minimale atteinte LeLEDbleuclignoterapidement une fois la themperature minim...

Страница 13: ...e minimale atteinte Le LED rouge clignote rapidement une fois la vitesse maximale atteinte 1 10 sec 1 2 4 RETOUR AUX RÉGLAGES D USINE 1 Désactiver l appareil 2 Enfoncez simultanément les boutons et du circuit imprimé et remettez sous tension Le LED bleu s allume le LED vert s allume 2 secondes plus tard et le LED rouge après 4 secon des Relâchez la pression sur les boutons dès que les 3 LED cligno...

Страница 14: ... sous garantie s ils sont vidés à des époques déterminées ou pendant un certain temps s ils sont chauffés au moyen d eaux industrielles de vapeur ou d eau qui contient des produits chimiques ou de grandes quantités d oxygène La qualité de l eau présente dans l in stallation doit être conforme à la directive VDI 2035 2 La garantie expire aussi quand les corps de chauffe sont installés dans un envir...

Страница 15: ...15 JAGA NV BRIZA 22 JDPC 002 US MANUEL 27200 20000096 11 02 2021 V 02 FR NOTES ...

Страница 16: ...Jaga N V Verbindingslaan 16 B 3590 Diepenbeek Tel 32 0 11 29 41 11 Fax 32 0 11 32 35 78 info jaga be www jaga com 27200 20000096 11 02 2021 ...

Отзывы: